MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jcla.22320

Медицинская библиотека · Journal of clinical laboratory analysis · 2017

Simple strategy for sensitive detection of dopamine using CdTe QDs modified glassy carbon electrode.

Yu Hong-Wei, Zhang Ze, Jiang Jing-Hui, Pan Hong-Zhi, Chang Dong

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Cellular and brain metabolism of dopamine can be correlated with a number of neurodegenerative disorders, our study was to explore a simple and efficient method to detect dopamine in real samples.

METHODS

A new quantum dots (CdTe QDs) could be prepared using the hydrothermal method, the electrochemical biosensor was established by dropping CdTe QDs on the surface of glassy carbon electrode (GCE).

RESULTS

The CdTe QDs/GCE exhibited the excellent electrochemical catalytic activity toward dopamine (DA) with good stability and high sensitivity in presence of interfering substances. The detection limit of DA was calculated by differential pulse voltammetry (DPV) as low as 0.3 μmol L-1 with a linear dynamic range of 1 μmol L-1 to 400 μmol L-1 .

CONCLUSION

In this paper, the proposed electrochemical biosensor could be effectively used for the direct and rapid detection of DA in human serum and urine samples.

Для цитирования: Yu Hong-Wei, Zhang Ze, Jiang Jing-Hui, Pan Hong-Zhi, Chang Dong. Simple strategy for sensitive detection of dopamine using CdTe QDs modified glassy carbon electrode.. Journal of clinical laboratory analysis. 2017. DOI: 10.1002/jcla.22320.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.