MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bbagen.2017.06.021

Медицинская библиотека · Biochimica et biophysica acta. General subjects · 2017

Conductive polymer-based bioelectrochemical assembly for in vitro cytotoxicity evaluation: Renoprotective assessment of Salvia officinalis against carbon tetrachloride induced nephrotoxicity.

Flampouri Evangelia, Sotiropoulou Νefeli-Sofia D, Mavrikou Sofia, Mouzaki-Paxinou Akrivi-Chara, Tarantilis Petros A, Kintzios Spyridon

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The rise of organic electronics represents one of the most prominent technological developments of the last two decades, with its interface with biological systems highlighting new directions of research. The "soft" nature of conducting polymers renders them unique platforms for cell-based microdevices, allowing their implementation in drug discovery, pharmaceutical effect analysis, environmental pollutant testing etc.

METHODS

Cellular adhesion, proliferation and viability experiments were carried out to verify the biocompatibility of a PEDOT conductive polymer surface. Cyclic voltammetry was employed for estimating the electrocatalytic activity of the renal cell/electrode interface. The nephrotoxicity agent CCl4 and the medicinal plant Salvia officinalis were used on the proposed assembly. Renal cell viability was also assayed through the MTT assay.

RESULTS

Renal cells were able to adhere and proliferate on the conducting polymer surface. Electrochemical responses of the polymer exhibited good correlation with cell number and CCl4 concentration. Amelioration of the CCl4-induced renotoxicity by co-incubation with Salvia officinalis extract was demonstrated by both the MTT assay and the electrode's capacitance.

CONCLUSIONS

A conducting polymer-based bioelectrochemical assembly was established for in vitro mammalian cytotoxicity/cytoprotection assessment, employing renal cell monolayers as the primary transducers for signal generation and biological sensing.

GENERAL SIGNIFICANCE: The knowledge on PEDOT mammalian cell biocompatibility and possible applications was expanded. The proposed interdisciplinary approach connects soft electronics with biology and could provide a useful tool for preliminary crude drug screening and bioactivity studies of natural products or plant extracts in vitro.

Для цитирования: Flampouri Evangelia, Sotiropoulou Νefeli-Sofia D, Mavrikou Sofia, Mouzaki-Paxinou Akrivi-Chara, Tarantilis Petros A, Kintzios Spyridon. Conductive polymer-based bioelectrochemical assembly for in vitro cytotoxicity evaluation: Renoprotective assessment of Salvia officinalis against carbon tetrachloride induced nephrotoxicity.. Biochimica et biophysica acta. General subjects. 2017. DOI: 10.1016/j.bbagen.2017.06.021.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.