MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1046/j.1537-2995.1994.341195065033.x

Медицинская библиотека · Transfusion · 1994

Antenatal platelet antibody testing by flow cytometry--results of a pilot study.

Marshall L R, Brogden F E, Roper T S, Barr A L

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Maternal platelet antibodies can cause fetomaternal alloimmune thrombocytopenia (FMAT), which has significant mortality and morbidity even in a first pregnancy. Prenatal diagnosis of FMAT has not previously been possible in the first affected pregnancy.

STUDY DESIGN AND

METHODS

Using flow cytometry, a sensitive, inexpensive test for the detection of platelet antibodies has been developed. It was adapted for use as a possible antenatal screening test, and 600 pregnant women were tested in a pilot study.

RESULTS

In the study group, two women tested positive for platelet-specific IgG antibodies, one for anti-HPA-1a and the other for anti-HPA-1a with anti-HLA. In each case, the fetus was found to be affected in utero, and treatment was initiated before successful delivery. Another woman was shown to have a platelet-reactive autoantibody without IgG specificity, and her infant was unaffected. A total of 95 (15.8%) of the women tested had HLA antibodies alone, and the majority demonstrated IgG specificity. On follow-up of 62 infants born to these women, none had thrombocytopenia; thus HLA antibodies were not shown to lead to FMAT in this study.

CONCLUSION

The flow cytometry-based test for platelet antibodies can detect clinically significant maternal antibodies, and it may be that early diagnosis and treatment in utero can enhance outcome in FMAT. A population screening program is planned to determine the predictive power of this test, in addition to its sensitivity, specificity, and efficiency.

Для цитирования: Marshall L R, Brogden F E, Roper T S, Barr A L. Antenatal platelet antibody testing by flow cytometry--results of a pilot study.. Transfusion. 1994. DOI: 10.1046/j.1537-2995.1994.341195065033.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.