MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.athoracsur.2010.01.058

Медицинская библиотека · The Annals of thoracic surgery · 2010

Simplified david reimplantation with reduction of anular size and creation of artificial sinuses.

Svensson Lars G, Cooper Maxwell, Batizy Lillian H, Nowicki Edward R

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The David reimplantation procedure is the preferred method of preserving tricuspid aortic valves during aortic root replacement. We report the results of a simplified approach to the David valve-sparing root reimplantation.

METHODS

Of 234 patients who underwent David reimplantation or some modification thereof, 129 operated on from January 2001 to June 2008 formed a consecutive single-surgeon series for midterm evaluation. Aortic anulus-left ventricular outflow tract and proximal tube graft size were reduced over a Hegar dilator to mean normal diameter based on body surface area, in the process creating neo-sinuses to accommodate cusp opening. Sixty-one patients (47%) had Marfan syndrome. Mean body surface area was 2.1 +/- 0.27 m(2). Preoperative aortic regurgitation grade was 1+ or less in 46%, 2+ in 26%, 3+ in 24%, and 4+ in 4.3%.

RESULTS

Left ventricular outflow tract sizing by Hegar dilator was 17 mm in 9.5% of patients, 19 mm in 18%, 21 mm in 56%, and 23 mm in 16%. Fifty-five (43%) had concomitant cusp repair. Postoperative aortic regurgitation grade was 0 in 98%, and none of the remaining had greater than 2+ AR. Postoperative mean aortic gradient was 9.0 +/- 3.5 mm Hg. No patient had intraoperative abandonment of the repair, and there were no postoperative deaths or strokes. Five-year survival was 99%, and 4 patients (3%) required late valve replacement.

CONCLUSIONS

A simple modification of the David operation, reducing anular size, and creating neo-sinuses preserves the aortic valve, eliminates aortic regurgitation, avoids aortic stenosis, and has favorable midterm results.

Для цитирования: Svensson Lars G, Cooper Maxwell, Batizy Lillian H, Nowicki Edward R. Simplified david reimplantation with reduction of anular size and creation of artificial sinuses.. The Annals of thoracic surgery. 2010. DOI: 10.1016/j.athoracsur.2010.01.058.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.