MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/jp.2014.151

Медицинская библиотека · Journal of perinatology : official journal of the California Perinatal Association · 2014

Catecholamine-resistant hypotension and myocardial performance following patent ductus arteriosus ligation.

Noori S, McNamara P, Jain A, Lavoie P M, Wickremasinghe A, Merritt T A, Solomon T, Sekar K, Attridge J T, Swanson J R, Gillam-Krakauer M, Reese J, Poindexter B B, Brook M, Auchus R J, Clyman R I, PDA Ligation/Hypotension Trial Investigators

Клиническое исследованиеСтатьяМногоцентровое исследованиеПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

OBJECTIVE

We performed a multicenter study of preterm infants, who were about to undergo patent ductus arteriosus ligation, to determine whether echocardiographic indices of impaired myocardial performance were associated with subsequent development of catecholamine-resistant hypotension following ligation.

STUDY

DESIGN

A standardized treatment approach for hypotension was followed at each center. Infants were considered to have catecholamine-resistant hypotension if their dopamine infusion was > 15 μg kg(-1)min(-1). Echocardiograms and cortisol measurements were obtained between 6 and 14 h after the ligation (prior to the presence of catecholamine-resistant hypotension).

RESULT: Forty-five infants were enrolled, 10 received catecholamines (6 were catecholamine-responsive and 4 developed catecholamine-resistant hypotension). Catecholamine-resistant hypotension was not associated with decreased preload, shortening fraction or ventricular output. Infants with catecholamine-resistant hypotension had significantly lower levels of systemic vascular resistance and postoperative cortisol concentration.

CONCLUSION

We speculate that low cortisol levels and impaired vascular tone may have a more important role than impaired cardiac performance in post-ligation catecholamine-resistant hypotension.

Для цитирования: Noori S, McNamara P, Jain A, Lavoie P M, Wickremasinghe A, Merritt T A, Solomon T, Sekar K, Attridge J T, Swanson J R, Gillam-Krakauer M, Reese J, Poindexter B B, Brook M, Auchus R J, Clyman R I, PDA Ligation/Hypotension Trial Investigators. Catecholamine-resistant hypotension and myocardial performance following patent ductus arteriosus ligation.. Journal of perinatology : official journal of the California Perinatal Association. 2014. DOI: 10.1038/jp.2014.151.