m+Medelevator.RU
← Поиск публикаций
Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2020

Assessing arsenic in human toenail clippings using portable X-ray fluorescence.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Fleming David E B, Crook Samantha L, Evans Colby T, Nader Michel N, Atia Manuel, Hicks Jason M T, Sweeney Ellen, McFarlane Christopher R, Kim Jong Sung, Keltie Erin, Adisesh Anil

Аннотация

Arsenic is a toxic metalloid which has been associated with a wide range of health effects in humans including skin abnormalities and an elevated risk of skin, bladder, kidney, and lung cancer, diabetes, and cardiovascular disease. The measurement of arsenic concentration in nail clippings is often used in population studies as an indicator of arsenic exposure. Portable X-ray fluorescence (XRF) is an emerging technique for measuring arsenic in nail clippings. In the current study, single toenail clippings from 60 Atlantic Canadian participants were assessed for arsenic using a new portable XRF approach. A mono-energetic portable XRF system using doubly curved crystal optics was used to measure each clipping for a total of 900 s. Energy spectra from each clipping were analyzed for arsenic characteristic X-rays to provide a normalized arsenic signal. The same clippings were then analyzed for arsenic concentration using a "gold standard" method of inductively coupled plasma mass spectrometry (ICP-MS). Nail clipping arsenic concentrations measured by ICP-MS ranged from 0.030 μg/g to 2.57 μg/g, with a median result of 0.14 μg/g. Portable XRF results for arsenic were compared against ICP-MS arsenic concentrations, with a linear equation of best fit determined between the two variables. A correlation coefficient of r = 0.77 was found from the 59 nail clippings returning an ICP-MS arsenic concentration above the limit of quantitation. When the comparison was limited to the 20 clippings having an XRF normalized signal at least twice as large as the associated uncertainty of measurement, the correlation coefficient was r = 0.89. With the selection of an arsenic concentration of 0.1 μg/g as a cut-off value between "exposed" and "non-exposed" individuals, the XRF method provided a test sensitivity of 76% and a specificity of 81%. The corresponding positive predictive value was 88% and the negative predictive value was 65%. The portable XRF technique used in this study shows promise as a means of assessing arsenic concentration in toenail clippings.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты