MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4187/respcare.05815

Медицинская библиотека · Respiratory care · 2017

The Role of Multidetector Computed Tomography and the Forced Oscillation Technique in Assessing Lung Damage in Adults With Cystic Fibrosis.

Lacerda Letícia S, Lopes Agnaldo J, Carvalho Alysson R S, Guimarães Alan R M, Firmida Mônica C, Castro Marcos C S, Mogami Roberto, Melo Pedro L

СтатьяПеревод в очереди

Аннотация

BACKGROUND

With increased survival rates and the consequent emergence of an adult population with cystic fibrosis (CF), developing novel tools for periodic evaluations of these patients has become a new challenge. Thus, we sought to determine the contribution of lung-volume quantification using multidetector computed tomography (CT) in adults with CF and to investigate the association between structural changes and functional abnormalities.

METHODS

This was a cross-sectional study in which 21 adults with CF and 22 control subjects underwent lung-volume quantification using multidetector CT. Voxel densities were divided into 4 bands: -1,000 to -900 Hounsfield units (HU) (hyperaerated region), -900 to -500 HU (normally aerated region), -500 to -100 HU (poorly aerated region), and -100 to 100 HU (non-aerated region). In addition, all participants performed pulmonary function tests including spirometry, body plethysmography, diffusion capacity for carbon monoxide, and the forced oscillation technique.

RESULTS

Adults with CF had more non-aerated regions and poorly aerated regions with lung-volume quantification using multidetector CT than controls. Despite these abnormalities, total lung volume measured by lung-volume quantification using multidetector CT did not differ between subjects and controls. Total lung capacity (TLC) measured by body plethysmography correlated with both total lung volume (rs = 0.71, P < .001) and total air volume (rs = 0.71, P < .001) as measured with lung-volume quantification using multidetector CT. While the hyperaerated regions correlated with the functional markers of gas retention in the lungs (increased residual volume (RV) and RV/TLC ratio), the poorly aerated regions correlated with the resistive parameters measured by the forced oscillation technique (increased intercept resistance and mean resistance). We also observed a correlation between normally aerated regions and highest pulmonary diffusion values (rs = 0.68, P < .001).

CONCLUSIONS

In adults with CF, lung-volume quantification using multidetector CT can destimate the lung volumes of compartments with different densities and determine the aerated and non-aerated contents of the lungs; furthermore, lung-volume quantification using multidetector CT is clearly related to pulmonary function parameters.

Для цитирования: Lacerda Letícia S, Lopes Agnaldo J, Carvalho Alysson R S, Guimarães Alan R M, Firmida Mônica C, Castro Marcos C S, Mogami Roberto, Melo Pedro L. The Role of Multidetector Computed Tomography and the Forced Oscillation Technique in Assessing Lung Damage in Adults With Cystic Fibrosis.. Respiratory care. 2017. DOI: 10.4187/respcare.05815.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.