MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/thx.2005.046615

Медицинская библиотека · Thorax · 2005

Mid-expiratory flow versus FEV1 measurements in the diagnosis of exercise induced asthma in elite athletes.

Dickinson J W, Whyte G P, McConnell A K, Nevill A M, Harries M G

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

A fall in FEV(1) of > or =10% following bronchoprovocation (eucapnic voluntary hyperventilation (EVH) or exercise) is regarded as the gold standard criterion for diagnosing exercise induced asthma (EIA) in athletes. Previous studies have suggested that mid-expiratory flow (FEF(50)) might be used to supplement FEV(1) to improve the sensitivity and specificity of the diagnosis. A study was undertaken to investigate the response of FEF(50) following EVH or exercise challenges in elite athletes as an adjunct to FEV(1).

METHODS

Sixty six male (36 asthmatic, 30 non-asthmatic) and 50 female (24 asthmatic, 26 non-asthmatic) elite athletes volunteered for the study. Maximal voluntary flow-volume loops were measured before and 3, 5, 10, and 15 minutes after stopping EVH or exercise. A fall in FEV(1) of > or =10% and a fall in FEF(50) of > or =26% were used as the cut off criteria for identification of EIA.

RESULTS

There was a strong correlation between DeltaFEV(1) and DeltaFEF(50) following bronchoprovocation (r = 0.94, p = 0.000). Sixty athletes had a fall in FEV(1) of > or =10% leading to the diagnosis of EIA. Using the FEF(50) criterion alone led to 21 (35%) of these asthmatic athletes receiving a false negative diagnosis. The lowest fall in FEF(50) in an athlete with a > or =10% fall in FEV(1) was 14.3%. Reducing the FEF(50) criteria to > or =14% led to 13 athletes receiving a false positive diagnosis. Only one athlete had a fall in FEF(50) of > or =26% in the absence of a fall in FEV(1) of > or =10% (DeltaFEV(1) = 8.9%).

CONCLUSION

The inclusion of FEF(50) in the diagnosis of EIA in elite athletes reduces the sensitivity and does not enhance the sensitivity or specificity of the diagnosis. The use of FEF(50) alone is insufficiently sensitive to diagnose EIA reliably in elite athletes.

Для цитирования: Dickinson J W, Whyte G P, McConnell A K, Nevill A M, Harries M G. Mid-expiratory flow versus FEV1 measurements in the diagnosis of exercise induced asthma in elite athletes.. Thorax. 2005. DOI: 10.1136/thx.2005.046615.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.