BACKGROUND

Awake fiberoptic tracheal intubation is an established method of securing difficult airways, but there are some reservations about its use because many practitioners find it technically complicated, time-consuming, and unpleasant for patients. Our main goal was to test the safety and efficacy of a 300-mm working length fiberscope (video rhino-laryngoscope) when used for awake nasotracheal intubation in difficult airway cases.

METHODS

This was a prospective, single-center study involving adult patients, having an ASA physical status between I and IV, with laryngopharyngeal pathology causing distorted airway anatomy. Awake nasotracheal intubation, using topical anesthesia and light sedation, was performed using a 300 mm long and 2.9 mm diameter fiberscope equipped with a lubricated reinforced endotracheal tube. The primary outcomes were the success and duration of the procedure. Patients' periprocedural satisfaction and other incidents were recorded.

RESULTS

We successfully intubated all 25 patients included in this study. The mean ±SD duration of the procedure, starting from the passage of the intubating tube through one of the nostrils until the endotracheal intubation, was 76 ± 36 seconds. Most of the patients showed no discomfort during the procedure with statistical significance between the No reaction Group with the Slight grimacing Group (95%CI 0.13, 0.53, p = 0.047) and the Heavy grimacing Group (95%CI 0.05, 0.83, p = 0.003). The mean ±SD satisfaction score 24 hours post-intervention was 1.8 ± 0.86 - mild discomfort. No significant incidents occurred.

CONCLUSIONS

Our study showed that a 300-mm working length flexible endoscope is fast, safe, and well-tolerated for nasotracheal awake intubation under challenging airways.

Для цитирования: Marchis Ioan Florin, Zdrehus Claudiu, Pop Sever, Radeanu Doinel, Cosgarea Marcel, Mitre Calin Iosif. Awake nasotracheal intubation with a 300-mm working length fiberscope: a prospective observational feasibility trial.. Brazilian journal of anesthesiology (Elsevier). 2021. DOI: 10.1016/j.bjane.2021.10.015.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.