MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1525-1497.2004.30357.x

Медицинская библиотека · Journal of general internal medicine · 2004

Communication factors in the follow-up of abnormal mammograms.

Poon Eric G, Haas Jennifer S, Louise Puopolo Ann, Gandhi Tejal K, Burdick Elisabeth, Bates David W, Brennan Troyen A

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To identify the communication factors that are significantly associated with appropriate short-term follow-up of abnormal mammograms.

DESIGN

Prospective longitudinal study involving medical record review and patient survey.

SETTING

Ten academically affiliated ambulatory medical practices in the Boston metropolitan area.

PARTICIPANTS

One hundred twenty-six women with abnormal mammograms requiring short-term (6 months) follow-up imaging.

MEASUREMENTS: Proportion of women in the study who received appropriate follow-up care.

RESULTS

Eighty-one (64%) of the women with abnormal mammograms requiring short-term follow-up imaging received the appropriate follow-up care. After adjusting for patients' age and insurance status, 2 communication factors were found to be independently associated with the delivery of appropriate follow-up care: 1). physicians' documentation of a follow-up plan in the medical record (adjusted odds ratio, 2.79; 95% confidence interval, 1.11 to 6.98; P =.029); and 2). patients' understanding of the need for follow-up (adjusted odds ratio, 3.86; 95% confidence interval, 1.50 to 9.96; P =.006). None of the patients' clinical or psychological characteristics were associated with the delivery of appropriate follow-up care.

CONCLUSIONS

Follow-up care for women with abnormal mammograms requiring short-term follow-up imaging is suboptimal. Documentation of the follow-up plan by the physician and understanding of the follow-up plan by the patient are important factors that are correlated with the receipt of appropriate follow-up care for these women. Interventions designed to improve the quality of result follow-up in the outpatient setting should address these issues in patient-doctor communication.

Для цитирования: Poon Eric G, Haas Jennifer S, Louise Puopolo Ann, Gandhi Tejal K, Burdick Elisabeth, Bates David W, Brennan Troyen A. Communication factors in the follow-up of abnormal mammograms.. Journal of general internal medicine. 2004. DOI: 10.1111/j.1525-1497.2004.30357.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.