MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1073/pnas.1116938109

Медицинская библиотека · Proceedings of the National Academy of Sciences of the United States of America · 2012

Tracking a complete voltage-sensor cycle with metal-ion bridges.

Henrion Ulrike, Renhorn Jakob, Börjesson Sara I, Nelson Erin M, Schwaiger Christine S, Bjelkmar Pär, Wallner Björn, Lindahl Erik, Elinder Fredrik

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Voltage-gated ion channels open and close in response to changes in membrane potential, thereby enabling electrical signaling in excitable cells. The voltage sensitivity is conferred through four voltage-sensor domains (VSDs) where positively charged residues in the fourth transmembrane segment (S4) sense the potential. While an open state is known from the Kv1.2/2.1 X-ray structure, the conformational changes underlying voltage sensing have not been resolved. We present 20 additional interactions in one open and four different closed conformations based on metal-ion bridges between all four segments of the VSD in the voltage-gated Shaker K channel. A subset of the experimental constraints was used to generate Rosetta models of the conformations that were subjected to molecular simulation and tested against the remaining constraints. This achieves a detailed model of intermediate conformations during VSD gating. The results provide molecular insight into the transition, suggesting that S4 slides at least 12 Å along its axis to open the channel with a 3(10) helix region present that moves in sequence in S4 in order to occupy the same position in space opposite F290 from open through the three first closed states.

Для цитирования: Henrion Ulrike, Renhorn Jakob, Börjesson Sara I, Nelson Erin M, Schwaiger Christine S, Bjelkmar Pär, Wallner Björn, Lindahl Erik, Elinder Fredrik. Tracking a complete voltage-sensor cycle with metal-ion bridges.. Proceedings of the National Academy of Sciences of the United States of America. 2012. DOI: 10.1073/pnas.1116938109.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.