[Surgical reduction of condylar fracture using lag screw].
Аннотация
OBJECTIVE
To evaluate the feasibility and result of application of lag screw osteosynthesis in condylar fracture.
METHODS
Six dislocated condylar fractures were treated with lag screw. Postoperative follow-up mean 7 months (range 3-13 months).
RESULTS
It showed no complaint on TMJ area from patients during the follow up, no facial asymmetry was found, no patient had malocclusion, 5 patients had mouth opening over 40 mm 3 months postoperatively, and all patients were satisfied with the treatment results.
CONCLUSION
Based on the clinical and radiological results the authers believe that lag screw technique is a feasible method for indicated condylar fracture.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.