International journal for numerical methods in biomedical engineering · 2020
Retrograde branched extension limb assembling stent of pararenal abdominal aortic aneurysm: A longitudinal hemodynamic analysis for stent graft migration.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Mei Yuqian, Xu Huanming, Ma Wei, Li Zhenfeng, Yang Rui, Yuan Hai, Peng Yan, Wu Muyang, Chen Zhangtao, Guo Wei, Gao Tianxin, Xiong Jiang, Chen Duanduan
Аннотация
PURPOSE: Pararenal abdominal aortic aneurysms (PRAAAs) are a life-threatening disease, and hemodynamic analysis may provide greater insight into the effectiveness and long-term outcomes of endovascular aneurysm repair (EVAR). However, the lack of patient-specific boundary conditions on the periphery compromises the accuracy. Windkessel (WK) boundary conditions coupled to hemodynamic follow-up models of a PRAAA patient, aims to provide insights into the link between hemodynamics and poor prognosis.
METHOD: One PRAAA patient underwent EVAR and reintervention after one branch of stent-graft (SG) had migrated. Totally five computational follow-up models were studied. Patient-specific flow data acquired via ultrasound were used to define the boundary conditions in the ascending aorta and the following three branches. Coupled zero-dimensional WK models representing the distal vasculature were used to define the outlet boundary conditions under the abdomen.
RESULTS: Flow divisions of the main SG branches were 40.7% and 24.7%, respectively. Time-averaged wall shear stress and oscillatory shear index (OSI) increased at the junction connected the SG branch and the stent leading to the right common iliac artery (RCIA) where the stent migrated. The OSI and relative residence time (RRT) value in superior mesenteric artery increased notably after the migration, the RRT continuously increased following the reintervention.
CONCLUSION: Unbalanced flow, resulting in locally high-speed flow, high WSS and OSI might significantly affect stent stability. Results suggest that diameters and interconnection design of stents in complex cases should take the flow division into consideration and computational simulations might be considered as a tool for intervention protocol design.
METHOD: One PRAAA patient underwent EVAR and reintervention after one branch of stent-graft (SG) had migrated. Totally five computational follow-up models were studied. Patient-specific flow data acquired via ultrasound were used to define the boundary conditions in the ascending aorta and the following three branches. Coupled zero-dimensional WK models representing the distal vasculature were used to define the outlet boundary conditions under the abdomen.
RESULTS: Flow divisions of the main SG branches were 40.7% and 24.7%, respectively. Time-averaged wall shear stress and oscillatory shear index (OSI) increased at the junction connected the SG branch and the stent leading to the right common iliac artery (RCIA) where the stent migrated. The OSI and relative residence time (RRT) value in superior mesenteric artery increased notably after the migration, the RRT continuously increased following the reintervention.
CONCLUSION: Unbalanced flow, resulting in locally high-speed flow, high WSS and OSI might significantly affect stent stability. Results suggest that diameters and interconnection design of stents in complex cases should take the flow division into consideration and computational simulations might be considered as a tool for intervention protocol design.