Repair of extensive thoracoabdominal aortic aneurysm with a tetrafurcate graft: midterm results of 63 cases.

Cheng Lijian, Huang Fuhua, Chang Qian, Zhu Junming, Yu Cuntao, Liu Yongmin, Zhang Haitao, Zheng Jun, Sun Li-Zhong

Клиническое исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

The objective is to present a method for maintaining the spinal cord blood supply and our midterm results for using a tetrafurcate graft in extensive thoracoabdominal aortic aneurysm (TAAA) repair.

METHODS

From August 2003 to October 2007, we used a tetrafurcate graft to perform repairs to TAAAs of Crawford extent II in 63 consecutive patients. The mean age of this group of patients was 39.98 +/- 10.62 years, and 46 (73%) of them were male. All of the procedures were performed under profound hypothermia with a short interval of circulatory arrest. T6 to T12 intercostal arteries were reconstructed as a "neo-intercostal artery" (N-IA) and were connected to an 8-mm sidearm of the graft to maintain the spinal cord blood supply. Visceral arteries were joined into a patch and were anastomosed to the end of the main graft. The left renal artery was anastomosed to an 8-mm sidearm or joined to the patch. The other 10-mm sidearms were anastomosed to iliac arteries.

RESULTS

With 100% follow-up, the early-mortality rate was 7.94%. The incidence of cerebral complications was 9.52%. Temporary paraplegia was observed in 2 patients, and paraparesis occurred in 1 patient. Pulmonary complication was the most common morbidity in this group (25.40%). Two patients with Marfan syndrome had N-IA artery pseudoaneurysms during follow-up. The mean survival time of this group was 50.64 +/- 2.13 months, with survival rates of 92.06% after 1 year, 88.38% after 2 years, and 86.11% after 3 years.

CONCLUSION

The N-IA may play an important role in spinal cord protection, and N-IA pseudoaneurysm should be avoided in Marfan syndrome patients. The use of a tetrafurcate graft is a reliable method for TAAA repair, with satisfactory midterm results.

Для цитирования: Cheng Lijian, Huang Fuhua, Chang Qian, Zhu Junming, Yu Cuntao, Liu Yongmin, Zhang Haitao, Zheng Jun, Sun Li-Zhong. Repair of extensive thoracoabdominal aortic aneurysm with a tetrafurcate graft: midterm results of 63 cases.. The heart surgery forum. 2010. DOI: 10.1532/hsf98.20091081.