MedElevator Войти в исследования
← Поиск публикаций
Respiratory care · 2015

Complications of Convex-Probe Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration: A Multi-Center Retrospective Study.

СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Çağlayan Benan, Yılmaz Aydın, Bilaçeroğlu Semra, Cömert Sevda Şener, Demirci Nilgün Y, Salepçi Banu

Аннотация

BACKGROUND: Infrequent serious complications of convex-probe endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) have been reported. The aim of this study was to assess serious complications related to convex-probe EBUS-TBNA and to determine the complication rate in a large group of subjects.

METHODS: In this retrospective study, a 15-item questionnaire on features of cases with EBUS-TBNA complications was sent to experienced bronchoscopists performing convex-probe EBUS-TBNA at 3 pulmonary centers. The medical records were then reviewed by these bronchoscopists to complete the questionnaire. Hemorrhage responsive to topical treatment, temporary laryngospasm/bronchospasm, transient oxygen desaturation, and fever lasting <24 h were excluded. Only complications requiring further treatment/intervention were considered serious. The rate of serious complications was calculated from the obtained data.

RESULTS: In a total of 3,123 cases within a 5-y period, EBUS-TBNA was performed for staging lung cancer in 15.8%, diagnosis in 67.5%, and diagnosis and staging in 16.3%. Of the 3,123, 11.6% had parenchymal lesions adjacent to major airways. EBUS-TBNA was performed 11,753 times (3.76/case) at 6,115 lymph node stations and lesions (1.92/station or lesion). Five serious complications were recorded (0.16%): fever lasting >24 h, infection of bronchogenic cyst, mediastinal abscess, pericarditis, and pneumomediastinitis with empyema, each in one case. Four complications occurred in cases diagnosed with benign disease by EBUS-TBNA. All complications were treated with broad-spectrum antibiotics. Four subjects were hospitalized for 21.7 ± 20.7 d.

CONCLUSIONS: Convex-probe EBUS-TBNA is a safe method in general. However, serious complications, including infections, can be encountered rarely. All precautions should be taken for complications before and during the procedure.

Предметные рубрики MeSH