Transmission of force to the hyoid bone during manual strangulation: Simulation using finite element numerical models.

Niort Fabrice, Godio-Raboutet Yves, Torrents Romain, Adalian Pascal, Léonetti Georges, Piercecchi-Marti Marie-Dominique, Thollon Lionel

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Strangulation is a medicolegal form of mechanical asphyxia, and can be difficult to identify if cutaneous damage to the neck is limited. We began by creating a numerical model of a hyoid bone with adjustable anthropometric parameters and then subjected our model to compression simulating a precision grip on the neck from the front.

MATERIALS AND

METHODS

We selected six bones from the 77 hyoid bones contained in the database we created during a previous study led by our laboratory, in which we demonstrated the sexual dimorphism of this bone and identified the minimal force required for fracture. The anthropometric characteristics of these six bones (angle, length and width) corresponded to those of the 10th, 50th and 90th percentiles from cluster 1 (male individuals) and cluster 2 (female individuals), respectively. After enhancing, developing and meshing the selected 3D models, we analysed and reproduced simulation conditions that were as close as possible to the in vivo conditions of neck strangulation from the front (area of pressure on the bone, tissue environment, and biological variability of this bone).

RESULTS

We modelled the six numerical hyoid bone models using the finite element method. For all models, the simulation of mechanical pressure applied to simulate anterior strangulation resulted in fractures. The forces required to produce these fractures matched the results obtained in the experimental testing of dissected hyoid bones.

CONCLUSION

Six finite element numerical models were created, covering the anthropometric morphological variability of the hyoid bone. These six models enabled numerical simulation of the in vivo behaviour of a hyoid bone subjected to one-handed strangulation.

Для цитирования: Niort Fabrice, Godio-Raboutet Yves, Torrents Romain, Adalian Pascal, Léonetti Georges, Piercecchi-Marti Marie-Dominique, Thollon Lionel. Transmission of force to the hyoid bone during manual strangulation: Simulation using finite element numerical models.. Forensic science international. 2015. DOI: 10.1016/j.forsciint.2015.10.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.