MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1148/radiology.205.2.9356634

Медицинская библиотека · Radiology · 1997

Normal placenta: gadolinium-enhanced dynamic MR imaging.

Marcos H B, Semelka R C, Worawattanakul S

СтатьяПеревод в очереди

Аннотация

PURPOSE: To establish the appearance of the normal placenta on dynamic, gadolinium-enhanced magnetic resonance (MR) images.

MATERIALS AND

METHODS

Eleven patients underwent MR imaging for suspected uterine (four patients) or placental (seven patients) abnormalities (but not placental insufficiency or intrauterine growth retardation). Unenhanced or gadolinium-enhanced, T1-weighted, fat suppressed, spoiled gradient-recalled-echo MR images and T2-weighted, half-Fourier, single-shot, spin-echo-train MR images were obtained. Two investigators retrospectively evaluated the images to determine the rate, pattern, and degree of placental contrast material enhancement with myometrial enhancement as a reference.

RESULTS

The diagnoses were normal placenta (six patients), abnormal placental position (four patients), and subchorionic hematoma (one patient). The placenta rapidly and intensely enhanced on images acquired immediately after contrast material administration and preceded substantial enhancement of the myometrium. Immediately postcontrast images showed closely packed 2-3-cm lobules of placental enhancement in third-trimester pregnancies and heterogeneous placental enhancement in second-trimester pregnancies. In all cases, placental enhancement became more homogeneous over time. The placenta could be readily distinguished from the myometrium. All neonates were healthy with no evidence of intrauterine growth retardation.

CONCLUSION

Normal placental enhancement is intense on immediately postcontrast images and precedes substantial myometrial enhancement. Third-trimester placentas exhibit a lobular pattern of enhancement, while second-trimester placentas exhibit heterogeneous enhancement.

Для цитирования: Marcos H B, Semelka R C, Worawattanakul S. Normal placenta: gadolinium-enhanced dynamic MR imaging.. Radiology. 1997. DOI: 10.1148/radiology.205.2.9356634.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.