MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.arthro.2009.10.012

Медицинская библиотека · Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association · 2010

Comparison between rigid and flexible systems for drilling the femoral tunnel through an anteromedial portal in anterior cruciate ligament reconstruction.

Silver Andrew G, Kaar Scott G, Grisell Margaret K, Reagan Jeffrey M, Farrow Lutul D

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: The purpose of this study was to compare the differences in femoral tunnel length and distance to the lateral anatomic structures when using standard and flexible guide pins for anterior cruciate ligament (ACL) femoral tunnel drilling through a medial portal.

METHODS

Using a medial arthroscopic portal in 10 cadaveric knees, we sequentially drilled straight and flexible guide pins into the center of the ACL femoral footprint using the same starting point. We recorded the interosseous length and distances to the peroneal nerve and the femoral origin of the lateral collateral ligament (LCL) for each pin.

RESULTS

The mean interosseous length was 43.5 mm for the flexible pin and 37.1 mm for the straight pin (P = .01). The mean distance to the peroneal nerve was 42.3 mm for the flexible pin and 37.8 mm for the straight pin (P = .33). The mean distance to the femoral origin of the LCL was 26.1 mm for the flexible pin and 13.4 mm for the straight pin (P = .003).

CONCLUSIONS

The use of commercially available flexible reamers and 42 degrees femoral guides results in longer femoral interosseous tunnel length than can be achieved with a straight guide pin. Femoral interosseous length consistently of 40 mm can be achieved with this technique and cannot be replicated with a rigid straight pin. This is advantageous for femoral tunnel drilling in an anatomic ACL reconstruction that uses suspensory fixation devices. There is minimal risk to the peroneal nerve and the femoral origin of the LCL unless lateral femoral wall blowout occurs.

CLINICAL RELEVANCE: Flexible pins allow longer femoral tunnels and safer distances from the LCL by use of a medial portal technique.

Для цитирования: Silver Andrew G, Kaar Scott G, Grisell Margaret K, Reagan Jeffrey M, Farrow Lutul D. Comparison between rigid and flexible systems for drilling the femoral tunnel through an anteromedial portal in anterior cruciate ligament reconstruction.. Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association. 2010. DOI: 10.1016/j.arthro.2009.10.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.