Journal of occupational health · 2025
A method for determining workers' exposure concentration to airborne nitrilotriacetic acid.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Yamada Ai, Ishii Kenta, Takeuchi Akito, Tashiro Tomiko, Endo Ginji, Ono-Ogasawara Mariko
Аннотация
OBJECTIVES: This study aimed to establish a method to determine workers' exposure concentrations to airborne nitrilotriacetic acid (NTA).
METHODS: The sampler used an air sampling cassette containing a glass-fiber filter (GFF). After sampling, NTA extracted from the GFF using ultrapure water was derivatized using a boron trifluoride-methanol complex methanol solution and analyzed using a gas chromatograph-mass spectrometer. The developed method was validated for the following parameters: retention efficiency, storage stability, method quantitation limit, and reproducibility.
RESULTS: The retention efficiency for NTA on the GFF was 94%-101%, with the relative SD indicating the overall reproducibility (range 0.9%-2.4%). NTA on the GFF was stable at 4°C for at least 7 days. The method quantitation limit was 4.8 μg per sample.
CONCLUSIONS: The developed method will be useful for risk assessments because it can determine workers' exposure concentrations to NTA ranging from 0.02 to 4 mg/m3 in a 240 L sampling volume; the quantitation limit is 4.8 μg per sample.
METHODS: The sampler used an air sampling cassette containing a glass-fiber filter (GFF). After sampling, NTA extracted from the GFF using ultrapure water was derivatized using a boron trifluoride-methanol complex methanol solution and analyzed using a gas chromatograph-mass spectrometer. The developed method was validated for the following parameters: retention efficiency, storage stability, method quantitation limit, and reproducibility.
RESULTS: The retention efficiency for NTA on the GFF was 94%-101%, with the relative SD indicating the overall reproducibility (range 0.9%-2.4%). NTA on the GFF was stable at 4°C for at least 7 days. The method quantitation limit was 4.8 μg per sample.
CONCLUSIONS: The developed method will be useful for risk assessments because it can determine workers' exposure concentrations to NTA ranging from 0.02 to 4 mg/m3 in a 240 L sampling volume; the quantitation limit is 4.8 μg per sample.