Invasive management of atrial tachycardias using a novel lattice-tip catheter combining high-density mapping and dual ablation properties: initial real-world experience.

Kariki Ourania, Mililis Panagiotis, Saplaouras Athanasios, Efremidis Theodoros, Dragasis Stylianos, Letsas Konstantinos P, Efremidis Michael

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Invasive management of atrial tachycardias(ATs) requires proper diagnosis of the mechanism followed by elimination of the responsible substrate. A novel lattice-tip catheter with both high-density mapping and dual ablation properties(radiofrequency-RF/pulsed field ablation-PFA) has been recently introduced for catheter ablation of atrial fibrillation. We present the first study to assess its performance in the management of ATs (diagnostic and therapeutic).

METHODS

Patients with documented ATs were selected. Activation mapping was used for the establishment of the AT mechanism. Confirmation with entrainment was performed, whenever appropriate. Accuracy of the activation mapping in diagnosis, acute ablation efficacy, and procedural characteristics were the study endpoints.

RESULTS

Twenty patients were included (12 cavotricuspid isthmus-dependent atrial flutters, 5 mitral flutters, 2 roof flutters, and 2 focal ATs). Proper diagnosis was established by activation mapping in all cases. The mean mapping time was 7.85 ± 3.06 min with 296.82 ± 150.9 mean mapping points/minute. The mean ablation time was 54.25 ± 42.97 s. Conversion to sinus rhythm during ablation was achieved in all cases with the exception of a roof flutter that converted to mitral flutter and a case of a parahisian AT in which ablation was not attempted. Patients that received ablation did not experience any arrhythmia recurrence in a mean follow up of 4.14 ± 0.91 months. No major or minor complications occurred.

CONCLUSION

The lattice-tip catheter and its dedicated electroanatomical mapping system provided sufficiently detailed activation mapping for the diagnosis of the AT mechanism. The delivered lesions were highly effective acutely, with no adverse events. However, limitations exist and should be acknowledged.

Для цитирования: Kariki Ourania, Mililis Panagiotis, Saplaouras Athanasios, Efremidis Theodoros, Dragasis Stylianos, Letsas Konstantinos P, Efremidis Michael. Invasive management of atrial tachycardias using a novel lattice-tip catheter combining high-density mapping and dual ablation properties: initial real-world experience.. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2024. DOI: 10.1007/s10840-024-01928-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.