Determination of duloxetine in human plasma by capillary electrophoresis with laser-induced fluorescence detection.

Musenga Alessandro, Amore Mario, Mandrioli Roberto, Kenndler Ernst, de Martino Ludovica, Raggi Maria Augusta

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A method based on capillary electrophoresis has been developed for the analysis of the novel antidepressant drug duloxetine in human plasma. The method makes use of laser-induced fluorescence detection after derivatisation of the analyte with 5-(4,6-dichlorotriazinyl)aminofluorescein at pH 11. A single step liquid/liquid extraction procedure with a mixture of hexane/2-propanol allows the sample clean-up with extraction yields always >or=84% and interference removal. The electrophoretic separation is achieved using uncoated fused silica capillaries (60.0 cm effective length, 75.0 cm total length, 50 microm internal diameter) and a background electrolyte composed of borate buffer (40 mM, pH 10.3), tetrabutylammonium bromide (10 mM), and acetone (10%, v/v). The applied voltage is 20 kV; the samples are injected by pressure (50 mbar x 8 s). The method has been fully validated in terms of linearity range (2.5-150 ng mL(-1)), LOD and LOQ (1.0 and 2.5 ng mL(-1), respectively), precision (R.S.D.<6.7%) and accuracy (recovery >78%). Application to samples obtained from patients under treatment with duloxetine gave good results. The method represents the first application of capillary electrophoresis to the analysis of duloxetine in human plasma.

Для цитирования: Musenga Alessandro, Amore Mario, Mandrioli Roberto, Kenndler Ernst, de Martino Ludovica, Raggi Maria Augusta. Determination of duloxetine in human plasma by capillary electrophoresis with laser-induced fluorescence detection.. Journal of chromatography. B, Analytical technologies in the biomedical and life sciences. 2009. DOI: 10.1016/j.jchromb.2009.02.059.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.