MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/s22124613

Медицинская библиотека · Sensors (Basel, Switzerland) · 2022

Non-Contact Hand Movement Analysis for Optimal Configuration of Smart Sensors to Capture Parkinson's Disease Hand Tremor.

Khwaounjoo Prashanna, Singh Gurleen, Grenfell Sophie, Özsoy Burak, MacAskill Michael R, Anderson Tim J, Çakmak Yusuf O

СтатьяПеревод в очереди

Аннотация

Parkinson’s disease affects millions worldwide with a large rise in expected burden over the coming decades. More easily accessible tools and techniques to diagnose and monitor Parkinson’s disease can improve the quality of life of patients. With the advent of new wearable technologies such as smart rings and watches, this is within reach. However, it is unclear what method for these new technologies may provide the best opportunity to capture the patient-specific severity. This study investigates which locations on the hand can be used to capture and monitor maximal movement/tremor severity. Using a Leap Motion device and custom-made software the volume, velocity, acceleration, and frequency of Parkinson’s (n = 55, all right-handed, majority right-sided onset) patients’ hand locations (25 joints inclusive of all fingers/thumb and the wrist) were captured simultaneously. Distal locations of the right hand, i.e., the ends of fingers and the wrist showed significant trends (p < 0.05) towards having the largest movement velocities and accelerations. The right hand, compared with the left hand, showed significantly greater volumes, velocities, and accelerations (p < 0.01). Supplementary analysis showed that the volumes, acceleration, and velocities had significant correlations (p < 0.001) with clinical MDS-UPDRS scores, indicating the potential suitability of using these metrics for monitoring disease progression. Maximal movements at the distal hand and wrist area indicate that these locations are best suited to capture hand tremor movements and monitor Parkinson’s disease.

Для цитирования: Khwaounjoo Prashanna, Singh Gurleen, Grenfell Sophie, Özsoy Burak, MacAskill Michael R, Anderson Tim J, Çakmak Yusuf O. Non-Contact Hand Movement Analysis for Optimal Configuration of Smart Sensors to Capture Parkinson's Disease Hand Tremor.. Sensors (Basel, Switzerland). 2022. DOI: 10.3390/s22124613.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.