Association Between Arterial Pulse Waveform Analysis and Mortality in Patients With Septic Shock: A Retrospective Cohort Study Using Japanese Diagnosis Procedure Combination Data.
Аннотация
Purpose: Specialized pressure transducers for arterial pulse waveform analysis (S-APWA) devices are dedicated kits connected to an arterial pressure catheter that monitors hemodynamic parameters, such as cardiac output, pulse pressure variation, and stroke volume variation, less invasively. While the association between the use of S-APWA devices and clinical outcomes in perioperative patients has been previously evaluated, its assessment in patients with septic shock remains inadequate. Materials and
Methods
This retrospective cohort study utilized a nationwide Diagnosis Procedure Combination database in Japan. Adult patients with septic shock admitted to the intensive care unit (ICU) with arterial pressure catheter placement on the admission day from August 2012 to February 2021 were included. Hospitalizations meeting the eligibility criteria were categorized into groups based on S-APWA device usage. The primary outcome, evaluated using Cox regression analysis, was 30-day all-cause mortality in the propensity score overlap-weighted population. Secondary outcomes included in-hospital mortality, ICU duration, and overall hospital stay.
Results
Among 5130 eligible hospitalizations, 643 were in the S-APWA group and 4487 were in the conventional pressure transducer group. Cox regression analysis within the propensity score overlap-weighted population showed no significant difference in 30-day mortality (adjusted hazard ratio: 0.94; 95% confidence interval: 0.9-1.38; P = .58). Logistic regression analysis indicated no significant differences in the in-hospital mortality. While the S-APWA group had prolonged ICU stays, no significant difference in the overall hospital stay was observed according to linear regression analyses.
Conclusions
Our study found no significant association between S-APWA use and 30-day mortality in patients with septic shock. These findings offer insights into optimizing monitoring systems in ICUs.