MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/jlp.jlp_148_18

Медицинская библиотека · Journal of laboratory physicians · 2019

Evaluation of loop-mediated isothermal amplification assay for detection of scrub typhus in patients with acute febrile illness presenting to a Tertiary Care Center in Puducherry, India.

Karthikeyan Patricia Anitha, Hoti Sugeerappa Laxmanappa, Kanungo Reba

СтатьяПеревод в очереди

Аннотация

PURPOSE: Scrub typhus an acute febrile illness has diverse clinical manifestations, which overlap with other febrile illnesses. Due to this reason, it is misdiagnosed, leading to inappropriate treatment, sometimes resulting in fatality. Thus, accurate diagnosis of scrub typhus is important for appropriate treatment. This study evaluated the loop-mediated isothermal amplification (LAMP) assay as a diagnostic test for scrub typhus among patients with fever.

MATERIALS AND

METHODS

A total of 50 cases of acute febrile illness clinically resembling scrub typhus, with or without an eschar, or cases of pyrexia of unknown origin were included in the study. Blood samples collected from these cases were subjected to detection of IgM antibodies to Orientia tsutsugamushi by ELISA, conventional groEL polymerase chain reaction (PCR), and the LAMP assay.

RESULTS

Twelve cases had fever for less than a week, and two had fever for more than 3 weeks. IgM antibodies to O. tsutsugamushi were detected in 37 out of 50 samples (74%). LAMP assay was positive in 33 samples (66%). groEL gene-based PCR detected 35 (70%) samples as positive. Two samples negative by LAMP assay were positive by this PCR. Twenty samples collected from patients with dengue, typhoid, and malaria tested by the LAMP assay were negative, indicating its good specificity. LAMP assay and the conventional groEL-based PCR could detect 72.7% and 74.3% of the samples, respectively before the 10th day after onset of fever, whereas IgM ELISA could detect only 40.5% of the 37 samples.

CONCLUSION

This study suggests that LAMP assay could be a useful diagnostic test for detecting scrub typhus in the acute phase of the illness and a cheaper alternative to other molecular methods in resource poor settings.

Для цитирования: Karthikeyan Patricia Anitha, Hoti Sugeerappa Laxmanappa, Kanungo Reba. Evaluation of loop-mediated isothermal amplification assay for detection of scrub typhus in patients with acute febrile illness presenting to a Tertiary Care Center in Puducherry, India.. Journal of laboratory physicians. 2019. DOI: 10.4103/jlp.jlp_148_18.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.