MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1510/icvts.2009.220319

Медицинская библиотека · Interactive cardiovascular and thoracic surgery · 2009

Manufacturing and placing a bespoke support for the Marfan aortic root: description of the method and technical results and status at one year for the first ten patients.

Pepper John, Golesworthy Tal, Utley Martin, Chan John, Ganeshalingam Skandadas, Lamperth Michael, Mohiaddin Raad, Treasure Tom

СтатьяПеревод в очереди

Аннотация

Fatal aortic dissection commonly occurs in Marfan syndrome. Prevention currently relies on elective replacement of the aortic root. We are evaluating the placement of a manufactured, bespoke external support derived from a computer aided design in a prospective study. In the first ten patients, measurements were made consistently of the ascending aorta at the level of closure of the aortic valve cusps from magnetic resonance imaging (MRI) studies taken preoperatively and at fixed intervals thereafter. Before and after images were presented for measurement amongst duplicate images of 37 unoperated Marfan patients to permit assessment of intra-observer measurement reproducibility. All images were presented in random sequence to a radiologist unaware of the research question. The largest difference between the preoperative measurement and that made at least one year after surgery was determined. All patients had surgery as planned without complications and were alive at one year. In eight of the ten patients, the largest observed change was a marked reduction in aortic root diameter. The primary objective of this surgery was achieved in each case, reinforcing the ascending aorta whilst leaving the native aortic valve intact and conserving the blood/endothelium interface.

Для цитирования: Pepper John, Golesworthy Tal, Utley Martin, Chan John, Ganeshalingam Skandadas, Lamperth Michael, Mohiaddin Raad, Treasure Tom. Manufacturing and placing a bespoke support for the Marfan aortic root: description of the method and technical results and status at one year for the first ten patients.. Interactive cardiovascular and thoracic surgery. 2009. DOI: 10.1510/icvts.2009.220319.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.