MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/jp.2012.138

Медицинская библиотека · Journal of perinatology : official journal of the California Perinatal Association · 2012

Passive cooling during transport of asphyxiated term newborns.

O'Reilly D, Labrecque M, O'Melia M, Bacic J, Hansen A, Soul J S

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the efficacy and safety of passive cooling during transport of asphyxiated newborns.

STUDY

DESIGN

Retrospective medical record review of newborns with perinatal asphyxia transported for hypothermia between July 2007 and June 2010.

RESULT: Of 43 newborns transported, 27 were passively cooled without significant adverse events. Twenty (74%) passively cooled newborns arrived with temperature between 32.5 and 34.5 °C. One newborn arrived with a temperature <32.5, and 6 (22%) had temperatures >34.5 °C. Time from birth to hypothermia was significantly shorter among passively cooled newborns compared with newborns not cooled (215 vs 327 min, P<0.01), even though time from birth to admission to Boston Children's Hospital was similar (252 vs 259 min, P=0.77). Time from birth to admission was the only significant predictor of increased time to reach target temperature (P=0.001).

CONCLUSION

Exclusive passive cooling achieves significantly earlier initiation of effective hypothermia for asphyxiated newborns but should not delay transport for active cooling.

Для цитирования: O'Reilly D, Labrecque M, O'Melia M, Bacic J, Hansen A, Soul J S. Passive cooling during transport of asphyxiated term newborns.. Journal of perinatology : official journal of the California Perinatal Association. 2012. DOI: 10.1038/jp.2012.138.