DOI 10.1111/jce.15545

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2022

Durability of left bundle branch area pacing.

Mehta Nikhil A, Saqi Bilal, Sabzwari Syed R A, Gupta Rahul, Vyas Apurva, Gordon Jeffrey, Cossu Sergio, Nazir Talha, Freudenberger Ronald, Bozorgnia Babak

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Left bundle branch area pacing (LBBAP) is a form of conduction system pacing. Long-term data on the safety and performance of LBBAP 1 year postdevice implantation has not been well described.

METHODS AND

RESULTS

Sixty-five patients (49% females) who received LBBAP for bradycardia indications using the SelectSecure 3830 lead (Medtronic) were retrospectively evaluated. Clinical variables were examined. Lead parameters were obtained at implant and during regular follow-up. Mean age of patients was 75.7 ± 10.1 years with left ventricular ejection fraction 59.8 ± 10.4%. Indications for pacing were atrioventricular block 55%, sinus node dysfunction 19%, tachy-brady syndrome 15%, atrioventricular node ablation 8%, and bail out cardiac resynchronization therapy 3%. Mean baseline QRS measured 120 ± 38 ms, paced QRS duration was 138 ± 22ms. Paced QRS narrowed by 24 ms in those with pre-existing left bundle branch block (BBB), increased by 1 ms in those with pre-existing right BBB, and increased by 42 ms in those with no BBB. LBBAP threshold at implant was 0.521 ± 0.153 V at 0.4 ms, and increased to 0.654 ± 0.186 V at 3 months (+26%), 0.707 ± 0.186 V at 6 months (+36%), and 0.772 ± 0.220 V at 12 months (+48%). Patients with left BBB showed the maximum benefit with QRS narrowing 24 ms. Pacing impedance remained unchanged with no procedure-related complications.

CONCLUSION

LBBAP is a durable form of conduction system pacing with pacing thresholds remaining relatively stable over 12 months post device implantation. Patients with left BBB display the narrowest paced QRS.

Для цитирования: Mehta Nikhil A, Saqi Bilal, Sabzwari Syed R A, Gupta Rahul, Vyas Apurva, Gordon Jeffrey, Cossu Sergio, Nazir Talha, Freudenberger Ronald, Bozorgnia Babak. Durability of left bundle branch area pacing.. Journal of cardiovascular electrophysiology. 2022. DOI: 10.1111/jce.15545.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.