MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/1735-9066.164513

Медицинская библиотека · Iranian journal of nursing and midwifery research · 2015

Evaluation of the alert line of partogram in recognizing the need for neonatal resuscitation.

Bolbol-Haghighi Nahid, Keshavarz Maryam, Delvarianzadeh Mehri, Molzami Sahar

СтатьяПеревод в очереди

Аннотация

BACKGROUND

A major problem of the first moments of childbirth, especially in "prolonged labor," is perinatal asphyxia which necessitates neonatal resuscitation. This study aimed at evaluating the alert line of the partogram in recognizing the need for neonatal resuscitation 20-30 s after delivery.

MATERIALS AND

METHODS

140 full-term pregnant women were kept under surveillance through using a partogram. In order to decide on the onset of resuscitation, the three indicators of fetal respiration, heart rate, and skin color were used 20-30 s after delivery. The findings from the evaluation of fetal conditions were compared to the position of the ultimate cervical dilatation graph to the alert line of the partogram, and through using appropriate statistical procedures, sensitivity, specificity, and positive and negative prediction values of the alert line to recognize the need for neonatal resuscitation were computed.

RESULTS

There was a significant relationship between the need for neonatal resuscitation within 20-30 seconds after delivery and the graph of the cervical dilatations on the partogram (P = 0.001). The indices of the alert line for predicting the need for resuscitation 20-30 s after birth had a sensitivity of 97.5%, specificity of 80.2%, positive prediction value of 97.2%, and negative prediction value of 98.7%.

CONCLUSIONS

In mothers who had normal vaginal delivery, with normal fetal heart rate, and with no oxytocin administration or omniotomy, the alert line showed appropriate sensitivity, specificity, and negative prediction value. So, it can assist in predicting the necessity of action for neonatal resuscitation 20-30 s after delivery.

Для цитирования: Bolbol-Haghighi Nahid, Keshavarz Maryam, Delvarianzadeh Mehri, Molzami Sahar. Evaluation of the alert line of partogram in recognizing the need for neonatal resuscitation.. Iranian journal of nursing and midwifery research. 2015. DOI: 10.4103/1735-9066.164513.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.