MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1248/cpb.c21-00109

Медицинская библиотека · Chemical & pharmaceutical bulletin · 2021

Purity Determination of Cyclophosphamide Hydrate by Quantitative 31P-NMR and Method Validation.

Uchiyama Nahoko, Hosoe Junko, Sugimoto Naoki, Ishizuki Kyoko, Koide Tatsuo, Murabayashi Mika, Miyashita Naoto, Kobayashi Kengo, Fujimine Yoshinori, Yokose Toshiyuki, Ofuji Katsuya, Shimizu Hitoshi, Hasebe Takashi, Asai Yumi, Ena Eri, Kikuchi Junko, Kiyota Kohei, Fujita Kazuhiro, Makino Yoshinobu, Yasobu Naoko, Iwamoto Yoshiaki, Miura Toru, Mizui Koji, Asakura Katsuo, Suematsu Takako, Muto Hitomi, Kohama Ai, Goto Takashi, Yasuda Masu, Ueda Tomohiko, Goda Yukihiro

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

Recently, quantitative NMR (qNMR), especially 1H-qNMR, has been widely used to determine the absolute quantitative value of organic molecules. We previously reported an optimal and reproducible sample preparation method for 1H-qNMR. In the present study, we focused on a 31P-qNMR absolute determination method. An organophosphorus compound, cyclophosphamide hydrate (CP), listed in the Japanese Pharmacopeia 17th edition was selected as the target compound, and the 31P-qNMR and 1H-qNMR results were compared under three conditions with potassium dihydrogen phosphate (KH2PO4) or O-phosphorylethanolamine (PEA) as the reference standard for 31P-qNMR and sodium 4,4-dimethyl-4-silapentanesulfonate-d6 (DSS-d6) as the standard for 1H-qNMR. Condition 1: separate sample containing CP and KH2PO4 for 31P-qNMR or CP and DSS-d6 for 1H-qNMR. Condition 2: mixed sample containing CP, DSS-d6, and KH2PO4. Condition 3: mixed sample containing CP, DSS-d6, and PEA. As conditions 1 and 3 provided good results, validation studies at multiple laboratories were further conducted. The purities of CP determined under condition 1 by 1H-qNMR at 11 laboratories and 31P-qNMR at 10 laboratories were 99.76 ± 0.43 and 99.75 ± 0.53%, respectively, and those determined under condition 3 at five laboratories were 99.66 ± 0.08 and 99.61 ± 0.53%, respectively. These data suggested that the CP purities determined by 31P-qNMR are in good agreement with those determined by the established 1H-qNMR method. Since the 31P-qNMR signals are less complicated than the 1H-qNMR signals, 31P-qNMR would be useful for the absolute quantification of compounds that do not have a simple and separate 1H-qNMR signal, such as a singlet or doublet, although further investigation with other compounds is needed.

Для цитирования: Uchiyama Nahoko, Hosoe Junko, Sugimoto Naoki, Ishizuki Kyoko, Koide Tatsuo, Murabayashi Mika, Miyashita Naoto, Kobayashi Kengo, Fujimine Yoshinori, Yokose Toshiyuki, Ofuji Katsuya, Shimizu Hitoshi, Hasebe Takashi, Asai Yumi, Ena Eri, Kikuchi Junko, Kiyota Kohei, Fujita Kazuhiro, Makino Yoshinobu, Yasobu Naoko, Iwamoto Yoshiaki, Miura Toru, Mizui Koji, Asakura Katsuo, Suematsu Takako, Muto Hitomi, Kohama Ai, Goto Takashi, Yasuda Masu, Ueda Tomohiko, Goda Yukihiro. Purity Determination of Cyclophosphamide Hydrate by Quantitative 31P-NMR and Method Validation.. Chemical & pharmaceutical bulletin. 2021. DOI: 10.1248/cpb.c21-00109.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.