MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1089/end.2023.0697

Медицинская библиотека · Journal of endourology · 2024

Estimating Surgical Urethral Length on Intraoperative Robot-Assisted Prostatectomy Images Using Artificial Intelligence Anatomy Recognition.

Bakker Aron F H A, de Nijs Joris V, Jaspers Tim J M, de With Peter H N, Beulens Alexander J W, van der Poel Henk G, van der Sommen Fons, Brinkman Willem M

СтатьяПеревод в очереди

Аннотация

Objective

To construct a convolutional neural network (CNN) model that can recognize and delineate anatomic structures on intraoperative video frames of robot-assisted radical prostatectomy (RARP) and to use these annotations to predict the surgical urethral length (SUL).

Background

Urethral dissection during RARP impacts patient urinary incontinence (UI) outcomes, and requires extensive training. Large differences exist between incontinence outcomes of different urologists and hospitals. Also, surgeon experience and education are critical toward optimal outcomes. Therefore, new approaches are warranted. SUL is associated with UI. Artificial intelligence (AI) surgical image segmentation using a CNN could automate SUL estimation and contribute toward future AI-assisted RARP and surgeon guidance.

Methods

Eighty-eight intraoperative RARP videos between June 2009 and September 2014 were collected from a single center. Two hundred sixty-four frames were annotated according to prostate, urethra, ligated plexus, and catheter. Thirty annotated images from different RARP videos were used as a test data set. The dice (similarity) coefficient (DSC) and 95th percentile Hausdorff distance (Hd95) were used to determine model performance. SUL was calculated using the catheter as a reference.

Results

The DSC of the best performing model were 0.735 and 0.755 for the catheter and urethra classes, respectively, with a Hd95 of 29.27 and 72.62, respectively. The model performed moderately on the ligated plexus and prostate. The predicted SUL showed a mean difference of 0.64 to 1.86 mm difference vs human annotators, but with significant deviation (standard deviation = 3.28-3.56).

Conclusion

This study shows that an AI image segmentation model can predict vital structures during RARP urethral dissection with moderate to fair accuracy. SUL estimation derived from it showed large deviations and outliers when compared with human annotators, but with a small mean difference (<2 mm). This is a promising development for further research on AI-assisted RARP.

Для цитирования: Bakker Aron F H A, de Nijs Joris V, Jaspers Tim J M, de With Peter H N, Beulens Alexander J W, van der Poel Henk G, van der Sommen Fons, Brinkman Willem M. Estimating Surgical Urethral Length on Intraoperative Robot-Assisted Prostatectomy Images Using Artificial Intelligence Anatomy Recognition.. Journal of endourology. 2024. DOI: 10.1089/end.2023.0697.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.