Precontoured Plate Fixation for Incomplete Atypical Diaphyseal Fracture of Femur using Three-Dimensional Printing Rapid Prototyping: Two Cases Reports.

Won Heejae, Baek Seung-Hoon, Kim Cheol-Hwan, Kim Dong-Hyeon, Yoon Jee-Wook, Kim Shin-Yoon

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Reconstruction intramedullary nail spanning the whole length of the femur has been the gold standard treatment for complete atypical diaphyseal fractures of the femur (ADF). However, in cases of incomplete ADF combined with severe bowing, this approach might have complications and lead to iatrogenic complete fracture. We report two cases of incomplete ADF with severe bowing using a precontoured plate (PCP) after rapid prototyping (RP) of the deformed femurs with three-dimensional printing (3DP) technology.

CASE PRESENTATION: Two patients presented with gradually worsening thigh pain, especially during walking. The patients had been using bisphosphonates for 4 and 10 years, respectively. Radiography showed an incomplete fracture in the lateral cortex of the right femur shaft. The lateral bowing angles measured in the affected femurs were 15° and 14°, and the anterior bowing angles were 20° and 16°, respectively. In bone scans, both patients showed hot uptake in the right mid-shaft of the femur. Preoperatively, the affected femur of the patient was reconstructed by 3DP RP using CT, and the plate was bent to the shape of the bone model. The ADF was fixed with a PCP using the minimally invasive plate osteosynthesis technique. Both patients were encouraged to start full weight-bearing and return to their preinjury activity level in daily life immediately after surgery. At 2 years postoperatively, radiography showed healing of the fracture site without recurrence of thigh pain and implant-related problems.

CONCLUSION

Although intramedullary nailing is the standard surgical treatment for complete ADF, PCP using 3DP RP could be an effective treatment option for incomplete ADF with severely curved femur.

Для цитирования: Won Heejae, Baek Seung-Hoon, Kim Cheol-Hwan, Kim Dong-Hyeon, Yoon Jee-Wook, Kim Shin-Yoon. Precontoured Plate Fixation for Incomplete Atypical Diaphyseal Fracture of Femur using Three-Dimensional Printing Rapid Prototyping: Two Cases Reports.. Orthopaedic surgery. 2020. DOI: 10.1111/os.12867.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.