Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2002
Atrial fibrillation threshold predicted long-term efficacy of pharmacological treatment of patients without structural heart disease.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Shirayama T, Shiraishi H, Yoshida S, Matoba Y, Imai H, Nakagawa M
Аннотация
AIMS: To ascertain if an electrophysiological study could predict long-term efficacy of anti-arrhythmic drugs in the treatment of lone atrial fibrillation.
METHODS AND RESULTS: Forty-four patients (36 males, 8 females, age 55.5 +/- 10.6) with paroxysmal atrial fibrillation were enrolled to undergo serial electrophysiological studies at the bedside. Two quadripolar catheters were inserted via the subclavian vein. Disopyramide (D: 2 mg/kg iv), cibenzoline (C: 1.4 mg/kg iv), aprindine (A: 2 mg/kg iv), pilsicainide (P: 2 mg/kg po) and flecainide (F: 3 mg/kg po) were tested. Atrial fibrillation threshold (AFT) was measured as the lowest current amplitude of rapid pacing (50 Hz for 1 s) to induce atrial fibrillation lasting more than 30 s. Before drug treatment, AFT was 3.9 +/- 0.3 mA. Pharmacological treatment raised AFT as follows: D 5.9 +/- 0.9 mA, C 7.6 +/- 1.2 mA, A 8.1 +/-1.1 mA, P 6.0 +/- 0.8 mA, F 7.3 +/- 1.1 mA. Recurrence of atrial fibrillation was observed during 1-year follow-up in 12% of cases when they were treated with a drug that raised AFT by 5 mA or more. On the other hand, the recurrence rate was 87% when patients were treated with a drug that raised AFT by less than 5 mA (P = 0.001).
CONCLUSION: AFT was a good predictor of long-term efficacy of pharmacological treatment against atrial fibrillation.
METHODS AND RESULTS: Forty-four patients (36 males, 8 females, age 55.5 +/- 10.6) with paroxysmal atrial fibrillation were enrolled to undergo serial electrophysiological studies at the bedside. Two quadripolar catheters were inserted via the subclavian vein. Disopyramide (D: 2 mg/kg iv), cibenzoline (C: 1.4 mg/kg iv), aprindine (A: 2 mg/kg iv), pilsicainide (P: 2 mg/kg po) and flecainide (F: 3 mg/kg po) were tested. Atrial fibrillation threshold (AFT) was measured as the lowest current amplitude of rapid pacing (50 Hz for 1 s) to induce atrial fibrillation lasting more than 30 s. Before drug treatment, AFT was 3.9 +/- 0.3 mA. Pharmacological treatment raised AFT as follows: D 5.9 +/- 0.9 mA, C 7.6 +/- 1.2 mA, A 8.1 +/-1.1 mA, P 6.0 +/- 0.8 mA, F 7.3 +/- 1.1 mA. Recurrence of atrial fibrillation was observed during 1-year follow-up in 12% of cases when they were treated with a drug that raised AFT by 5 mA or more. On the other hand, the recurrence rate was 87% when patients were treated with a drug that raised AFT by less than 5 mA (P = 0.001).
CONCLUSION: AFT was a good predictor of long-term efficacy of pharmacological treatment against atrial fibrillation.