INTRODUCTION

The aim of the study was to evaluate the mortality and the outcomes of femoral revision in periprosthetic femoral fractures (PFF) using a titanium modular fluted tapered stem.

METHODS

We retrospectively reviewed femoral revisions performed for PFF with a titanium modular fluted tapered stem in 25 patients. The average age was 74.32 years. In 21 patients the type of fracture was Vancouver B2 and type B3 in 4 cases. The mean follow-up was 29.16 (0.83-104.1) months SD ± 29.49.

RESULTS

The 30-day and 1-year mortality were 8% and 12% respectively. The mean value of the Charlson Comorbidity Index was 4.8 and the mean value of ASA score was 2.4. The average time to surgery from admittance was 5.45 days with 20% of patients operated on within 48 hours. A significant correlation was found between ASA score and mortality. The mean HHS was 76 points; good-excellent results were recorded in 56% of patients. 72% had no pain and 28% had slight pain (VAS 1-3). 52% of patients were able to walk without pain, limp or aids. The mean implant subsidence was 1.57 mm and superior to 5 mm in 2 cases. As complications we recorded 4 implant dislocations (16%) and 2 infections. Reoperation rate was 12%.

CONCLUSIONS

Femoral revision with a modular fluted tapered stem in patients with periprosthetic fractures results in good clinical and radiological outcomes. However, mortality remains high and, despite the modularity design, dislocation is the most frequent complication.

Для цитирования: Munegato Daniele, Caminita Agostino Dario, Sotiri Romeo, Rossi Andrea, Bigoni Marco, Zatti Giovanni. Femoral revision in periprosthetic fractures using a titanium modular fluted tapered stem: mortality and clinical and radiological outcomes.. Hip international : the journal of clinical and experimental research on hip pathology and therapy. 2020. DOI: 10.1177/1120700020971313.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.