MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.fas.2011.05.001

Медицинская библиотека · Foot and ankle surgery : official journal of the European Society of Foot and Ankle Surgeons · 2011

Functional outcome of ankle fracture patients treated with biodegradable implants.

Rangdal Sushil, Singh Daljit, Joshi Narendra, Soni Ashwani, Sament Radheshyam

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Biodegradable devices have been developed to overcome the disadvantages of metallic implants especially the need for their subsequent removal, though they have their own drawbacks like poor mechanical properties and tissue reactions. Aim of this prospective study was to access the outcome of bimalleolar fractures fixed with biodegradable plates and screws.

METHODS

A prospective study was conducted between July 2006 and November 2008 comprising of sixteen patients with unilateral bimalleolar fractures. Fibula fractures were fixed with biodegradable plates and medial malleoli with screws. Patients were followed at two weeks, six weeks, three months, six months, twelve months and eighteen months. Final evaluation was done using Olerud Molander ankle score.

RESULTS

Six patients had excellent results; four patients had good results and six patients had fair performance. No patient in this series had a poor outcome. One patient had both pain and swelling at 14 weeks postoperatively which settled down with debridement and antibiotics. None of the patients needed implant removal.

CONCLUSION

Biodegradable plates and screws when used to fix bimalleolar fracture along with restricted weight bearing, provide satisfactory fracture healing, good functional results and reduce the need of implant removal.

Для цитирования: Rangdal Sushil, Singh Daljit, Joshi Narendra, Soni Ashwani, Sament Radheshyam. Functional outcome of ankle fracture patients treated with biodegradable implants.. Foot and ankle surgery : official journal of the European Society of Foot and Ankle Surgeons. 2011. DOI: 10.1016/j.fas.2011.05.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.