MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1074/jbc.m104932200

Медицинская библиотека · The Journal of biological chemistry · 2001

Elucidation of the differences between the 430- and 455-nm absorbing forms of P450-isocyanide adducts by resonance Raman spectroscopy.

Tomita T, Ogo S, Egawa T, Shimada H, Okamoto N, Imai Y, Watanabe Y, Ishimura Y, Kitagawa T

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Alkylisocyanide adducts of microsomal P450 exist in two interconvertible forms, each giving the Soret maximum around 430 or 455 nm. This is demonstrated with a rabbit liver P450 2B4. Resonance Raman spectra of the 430- and 455-nm forms were examined for typical P450s of the two types as well as for P450 2B4 because the 430-nm form of P450 2B4 is liable to change into P420. P450cam and P450nor were selected as a model of the 430- and 455-nm forms, respectively. For the n-butyl isocyanide (CNBu) adduct, the Fe(II)-CNBu stretching band was observed for the first time at 480/467 cm(-1) for P450cam and at 471/459 cm(-1) for P450nor with their (12)CNBu/(13)CNBu derivatives. For P450cam, but not P450nor, other (13)C isotope-sensitive bands were observed at 412/402, 844/835, and 940/926 cm(-1). The C-N stretching mode was identified by Fourier transform IR spectroscopy at 2116/2080 cm(-1) for P450cam and at 2148/2108 cm(-1) for P450nor for the (12)C/(13)C derivatives. These findings suggest that the binding geometry of isocyanide differs between the two forms-bent and linear structures for P450cam-CNBu and P450nor-CNBu, respectively. In contrast, in the ferric state, the Raman (13)C isotopic frequency shifts, and the IR C-N stretching frequencies (2213/2170 and 2215/2172 cm(-1)) were similar between P450cam and P450nor, suggesting similar bent structures for both.

Для цитирования: Tomita T, Ogo S, Egawa T, Shimada H, Okamoto N, Imai Y, Watanabe Y, Ishimura Y, Kitagawa T. Elucidation of the differences between the 430- and 455-nm absorbing forms of P450-isocyanide adducts by resonance Raman spectroscopy.. The Journal of biological chemistry. 2001. DOI: 10.1074/jbc.m104932200.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.