Analytical and bioanalytical chemistry · 2026
Rapid analysis of mercury ion in real samples via ion-imprinted nanoparticle-based test strips.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Wang Rui, Xue Junping, Tan Chunyu, Jia Birong, Zhang Peng, Chen Lingxin, Li Jinhua, Song Zhihua
Аннотация
Mercury ion (Hg2+) contamination poses severe threats to ecological systems and human health, necessitating the development of facile and rapid monitoring methodologies. Herein, a fluorescence sensing system integrating ion-imprinted polymer (IIP) nanoparticle (NP)-based test strips with a miniaturized fluorimeter was fabricated for rapid quantitative analysis of Hg2+ in complicated matrix samples. First, CdTe quantum dot (QD)-coated silica (CdTe@SiO2) NPs and Hg2+-imprinted polymer-functionalized CdTe@SiO2 (Hg-IIPs@CdTe@SiO2) NPs were synthesized via an ion-imprinting strategy using Hg2+ as the template ion via ion-imprinting technology. Critical synthetic parameters, including the feed ratios of functional monomer, cross-linker, and catalyst, as well as the loading volume of QDs, were systematically optimized. Characterizations verified that the as-prepared Hg-IIPs@CdTe@SiO2 NPs displayed regular spherical morphology, desirable component distribution, and favorable fluorescence performance. Further mechanistic investigation revealed that Hg2+ effectively quenched the intrinsic fluorescence of Hg-IIPs@CdTe@SiO2 NPs via a combination of dynamic quenching and Förster resonance energy transfer (FRET). Benefiting from the good fluorescence properties of specific recognition of the system, the constructed sensing platform achieved high sensitivity with a limit of detection (LOD) of 9.1 ng/L, superior anti-interference selectivity, and satisfactory reproducibility and storage stability (relative standard deviation, RSD < 5%). Green Analytical Procedure Index (GAPI) assessment confirmed the eco-friendly feature of the proposed detection strategy. Finally, the developed sensing system was successfully applied for Hg2+ quantification in real samples, highlighting its promising application prospect for environmental supervision, food safety, and pharmaceutical inspection.