MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1039/d3ay01308a

Медицинская библиотека · Analytical methods : advancing methods and applications · 2024

An impedimetric immunosensor for diagnosis of Brazilian spotted fever in blood plasma.

Araújo Pereira Marx Osório, Júnior Álvaro Ferreira, Batista Rodrigues Edson Silvio, Mulser Helena, Nascimento de Mello E Silva Giovanna, Pio Dos Santos Wallans Torres, de Souza Gil Eric

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Brazilian spotted fever (BSF) is a serious disease of medical importance due to its rapid evolution and high lethality. The effectiveness of the treatment mainly depends on the rapid diagnosis, which is currently performed by indirect immunofluorescence and PCR tests, which require high costs and laboratory structure. In order to propose an alternative methodology, we sought to develop an impedimetric immunosensor (IM) based on the immobilization of specific IgY antibodies for IgG anti Rickettsia rickettsii, using blood plasma from capybara (Hydrochoerus hydrochaeris), for characterization, validation and applications of the ready IM. IM selectivity was observed when comparing capybara reagent IgG (IgGcr) readings with non-reagent IgG (IgGnr). A reagent IgG calibration curve was obtained, from which the limits of detection (LOD) and quantification (LOQ) of 1.3 ng mL-1 and 4.4 ng mL-1 were calculated, respectively. The accuracy tests showed that different concentrations of IgGcr showed a maximum deviation of 20.0%, with CI between 90.00% and 95.00%. Intermediate precision tests showed a relative standard deviation of 2.09% for researcher 1 and 2.61% for researcher 2, and the F test showed no significant difference between the recovery values found between the two analysts, since Fcal 1.56 < 5.05 and P-value 0.48 > 0, 05. Therefore, an impedimetric immunosensor was developed to detect anti BSF IgG in capybara blood plasma, which greatly contributes to the improvement of diagnostic tests, cost reduction and ease of execution.

Для цитирования: Araújo Pereira Marx Osório, Júnior Álvaro Ferreira, Batista Rodrigues Edson Silvio, Mulser Helena, Nascimento de Mello E Silva Giovanna, Pio Dos Santos Wallans Torres, de Souza Gil Eric. An impedimetric immunosensor for diagnosis of Brazilian spotted fever in blood plasma.. Analytical methods : advancing methods and applications. 2024. DOI: 10.1039/d3ay01308a.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.