DOI 10.1080/01616412.2015.1115222
Altered bulbocavernosus reflex in patients with multiple system atrophy.
Аннотация
OBJECTIVES
Multiple system atrophy (MSA) is characterized by a combination of symptoms including autonomic dysfunction, parkinsonism, cerebellar ataxia, and cortico-spinal disorders. The disease can have either predominant parkinsonism or cerebellar features (MSA-P and MSA-C, respectively). The measurement of the bulbocavernosus reflex (BCR) and pudendal nerve somatosensory-evoked potentials (PSEPs) was originally developed to diagnose diabetic cystopathy and other neuropathologic diseases that share similar symptoms with MSA. We investigated the relationship between abnormalities of neurophysiological parameters and MSA, and estimated the potential value of BCR.
METHODS
Fifty-one MSA patients (28 and 23 MSA-P and 23 MSA-C patients, respectively) and 30 healthy controls who were seen at the Department of Neurology were included in the study. A Keypoint EMG/EP system was used to test BCR and PSEPs, and the latencies and amplitudes were recorded for statistical analyses.
RESULTS
The BCR was elicited in 78.4% patients with MSA (22/28 MSA-P, 18/23 MSA-C). Prolonged BCR latencies were found in patients with MSA compared with healthy controls (p < 0.001). BCR amplitudes were significantly lower in the MSA group than the control group (p < 0.001). PSEP P41 amplitudes were not significantly different between the MSA and control groups in males (p = 0.608) or females (p = 0.897). There were no significant differences in PSEP latencies among the MSA-P, MSA-C, and control groups (p = 1.0, p = 0.263, and p = 0.060, respectively).
DISCUSSION: MSA patients exhibit prolonged BCR latencies and lower amplitudes, which provides a rough anatomical localization of nervous system lesions in MSA patients.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.