MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pntd.0001307

Медицинская библиотека · PLoS neglected tropical diseases · 2011

Diagnostic accuracy of a loop-mediated isothermal PCR assay for detection of Orientia tsutsugamushi during acute Scrub Typhus infection.

Paris Daniel H, Blacksell Stuart D, Nawtaisong Pruksa, Jenjaroen Kemajittra, Teeraratkul Achara, Chierakul Wirongrong, Wuthiekanun Vanaporn, Kantipong Pacharee, Day Nicholas P J

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

There is an urgent need to develop rapid and accurate point-of-care (POC) technologies for acute scrub typhus diagnosis in low-resource, primary health care settings to guide clinical therapy.

METHODOLOGY/PRINCIPAL FINDINGS: In this study we present the clinical evaluation of loop-mediated isothermal PCR assay (LAMP) in the context of a prospective fever study, including 161 patients from scrub typhus-endemic Chiang Rai, northern Thailand. A robust reference comparator set comprising following 'scrub typhus infection criteria' (STIC) was used: a) positive cell culture isolate and/or b) an admission IgM titer ≥1∶12,800 using the 'gold standard' indirect immunofluorescence assay (IFA) and/or c) a 4-fold rising IFA IgM titer and/or d) a positive result in at least two out of three PCR assays. Compared to the STIC criteria, all PCR assays (including LAMP) demonstrated high specificity ranging from 96-99%, with sensitivities varying from 40% to 56%, similar to the antibody based rapid test, which had a sensitivity of 47% and a specificity of 95%.

CONCLUSIONS/SIGNIFICANCE: The diagnostic accuracy of the LAMP assay was similar to realtime and nested conventional PCR assays, but superior to the antibody-based rapid test in the early disease course. The combination of DNA- and antibody-based detection methods increased sensitivity with minimal reduction of specificity, and expanded the timeframe of adequate diagnostic coverage throughout the acute phase of scrub typhus.

Для цитирования: Paris Daniel H, Blacksell Stuart D, Nawtaisong Pruksa, Jenjaroen Kemajittra, Teeraratkul Achara, Chierakul Wirongrong, Wuthiekanun Vanaporn, Kantipong Pacharee, Day Nicholas P J. Diagnostic accuracy of a loop-mediated isothermal PCR assay for detection of Orientia tsutsugamushi during acute Scrub Typhus infection.. PLoS neglected tropical diseases. 2011. DOI: 10.1371/journal.pntd.0001307.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.