MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/ijlh.13409

Медицинская библиотека · International journal of laboratory hematology · 2020

Higher coagulation activity in hip fracture patients: A case-control study using rotational thromboelastometry.

Tsantes Andreas G, Trikoupis Ioannis G, Papadopoulos Dimitrios V, Tsante Konstantina A, Mavrogenis Andreas F, Koulouvaris Panagiotis, Savvidou Olga D, Kontogeorgakos Vasilios A, Piovani Daniele, Kriebardis Anastasios G, Bonovas Stefanos, Papagelopoulos Panayiotis J, Tsantes Argirios E

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Trauma-induced coagulopathy has been extensively investigated in the multitrauma setting, but only sparsely following moderate orthopedic trauma. The purpose of this study was to evaluate changes in the hemostatic profile of patients with hip fractures, using rotational thromboelastometry (ROTEM).

METHODS

198 patients with hip fractures who underwent surgery were included in the study. A matched group of 52 healthy individuals was also enrolled. Demographics, conventional laboratory assays, and ROTEM parameters were recorded and compared between patients and healthy adults. The preoperative and postoperative ROTEM values of fractured patients were also compared.

RESULTS

The conventional coagulation assays were similar for the 2 groups. However, several ROTEM parameters including EXTEM MCF (P < .001), EXTEM alpha angle (P < .001), INTEM MCF (P < .001), INTEM A10 (P < .001), and INTEM alpha angle (P < .001) significantly differed between the 2 groups indicating a higher coagulation potential following hip fractures. Also, fractured patients had significantly lower INTEM and EXTEM CT values (P = .008 and P = .012, respectively) and significantly lower INTEM and EXTEM CFT values (P < .001). Adjusted analysis for confounders further confirmed the direct relationship between hip fracture and higher coagulation activity. Last, INTEM CT and CFT significantly decreased (P = .008 and P < .001, respectively), while INTEM MCF, A10, and alpha angle significantly increased (P < .001) postoperatively, indicating that surgery further increases the coagulation potential.

CONCLUSION

A higher coagulation activity following hip fractures and surgical treatment can be detected by ROTEM shortly after the injury, even when this is undetectable by conventional coagulation assays.

Для цитирования: Tsantes Andreas G, Trikoupis Ioannis G, Papadopoulos Dimitrios V, Tsante Konstantina A, Mavrogenis Andreas F, Koulouvaris Panagiotis, Savvidou Olga D, Kontogeorgakos Vasilios A, Piovani Daniele, Kriebardis Anastasios G, Bonovas Stefanos, Papagelopoulos Panayiotis J, Tsantes Argirios E. Higher coagulation activity in hip fracture patients: A case-control study using rotational thromboelastometry.. International journal of laboratory hematology. 2020. DOI: 10.1111/ijlh.13409.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.