MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cca.2024.120027

Медицинская библиотека · Clinica chimica acta; international journal of clinical chemistry · 2024

The diagnostic accuracy of HE4 in the differential diagnosis of pleural effusions.

Bérgamo Silvia, Trapé Jaume, González-García Laura, González-Fernández Carolina, Vergara Carme, la-Torre Noelia de-, Bosch-Presegué Laia, Otero-Viñas Marta, Catot Silvia, Crespo-Casal Manuel, Rives-Jimenez Jose, Arnau Anna, Costa Roser, Cugat José Ramón, Gonzalez-Sánchez Francesc, Pla-Salas Xavier, Sant Francesc

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Pleural effusions are challenging to diagnose, with approximately 20-50% of malignant effusions not diagnosed by cytology. Human epididymal protein 4 (HE4) may be useful in the differential diagnosis of pleural effusions. In serum, this biomarker shows false-positive results in some benign diseases. The aim of this study was to evaluate the diagnostic utility of HE4 in this setting and to identify false positives.

METHODS

Concentrations of HE4, adenosine deaminase, % polynuclear cells, and C-reactive protein, were determined in 238 pleural fluid samples and the estimated glomerular filtration rate (eGFr) in serum.

RESULTS

HE4 values ​​differed significantly (p < 0.01) between malignant [median (IQR)] [1065 (2085)] pmol/L and benign effusions [699 (589)] pmol/L. HE4 concentrations in gynecological and pulmonary tumors were significantly higher than in other tumors. For a cut-off point of 3050 pmol/L, 22 % sensitivity and 100 % specificity were obtained. In patients with benign disease, significant increases in HE4 were identified only in those with eGFr < 30 mL/min/1.73 m2 [1050(596)] pmol/L, and not in those with eGFr > 30 mL/min/1.73 m2 [597(532)] pmol/L). Two cut-offs were established for maximum specificity, depending on the eGFr: 3050 pmol/L for eGFr < 30 mL/min/1.73 m2 and 1992 pmol/L for eGFr > 30 mL/min/1.73 m2. A sensitivity of 28.5 % was obtained for patients with eGFr > 30 mL/min/1.73 m2 and 36.3 % for patients with eGFr < 30 mL/min/1.73 m2. The sensitivity using a specific cut-off point was 29.7 %.

CONCLUSIONS

The determination of HE4 in pleural fluids demonstrates high specificity and low sensitivity. The use of specific cutoff points that are clinically adjusted improves sensitivity while maintaining maximum specificity.

Для цитирования: Bérgamo Silvia, Trapé Jaume, González-García Laura, González-Fernández Carolina, Vergara Carme, la-Torre Noelia de-, Bosch-Presegué Laia, Otero-Viñas Marta, Catot Silvia, Crespo-Casal Manuel, Rives-Jimenez Jose, Arnau Anna, Costa Roser, Cugat José Ramón, Gonzalez-Sánchez Francesc, Pla-Salas Xavier, Sant Francesc. The diagnostic accuracy of HE4 in the differential diagnosis of pleural effusions.. Clinica chimica acta; international journal of clinical chemistry. 2024. DOI: 10.1016/j.cca.2024.120027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.