MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1532-849x.2008.00410.x

Медицинская библиотека · Journal of prosthodontics : official journal of the American College of Prosthodontists · 2008

Effects of six surface treatment methods on the surface roughness of a low-fusing and an ultra low-fusing feldspathic ceramic material.

Dalkiz Mehmet, Sipahi Cumhur, Beydemir Bedri

СтатьяПеревод в очереди

Аннотация

PURPOSE: The purpose of this in vitro study was to determine the effects of six surface treatment methods on the surface roughness of two feldspathic ceramic materials.

MATERIALS AND

METHODS

One hundred twenty metal discs were cast (Remanium CS). A low-fusing feldspathic ceramic (Vita Omega 900) was fired onto 60 metal discs, and an ultra low-fusing feldspathic ceramic (Finesse) was fired onto the other 60 metal discs. Six surface treatment methods were selected: (1) autoglazing (AUG), (2) overglazing (OVG), (3) polishing (POL), (4) fine diamond disc grinding + polishing + autoglazing (FDPA), (5) coarse diamond disc grinding + polishing + autoglazing (CDPA), (6) polishing + autoglazing (PA). Omega specimens were assigned to six experimental groups representing six surface treatment methods (Om-AUG, Om-OVG, Om-POL, Om-FDPA, Om-CDPA, Om-PA) (n = 10). Finesse specimens were also assigned to six experimental groups (Fn-AUG, Fn-OVG, Fn-POL, Fn-FDPA, Fn-CDPA, Fn-PA) (n = 10). Treated ceramic surfaces were examined by means of profilometry and transmission electron microscopy.

RESULTS

In Omega groups mean roughness values ranged as follows: group Om-AUG = Om-POL > Om-OVG > Om-CDPA = Om-FDPA > Om-PA (p < 0.001). No significant difference was found between groups Om-AUG/Om-POL and Om-CDPA/Om-FDPA (p > 0.05). In Finesse groups mean roughness values ranged as follows: Fn-CDPA > Fn-FDPA = Fn-AUG = Fn-POL = Fn-OVG > Fn-PA (p < 0.001). No significant difference was found between Fn-FDPA, Fn-AUG, Fn- POL and Fn-OVG (p > 0.05).

CONCLUSIONS

For both ceramic types, the smoothest surfaces were obtained with polishing prior to autoglazing. Diamond disc grinding prior to polishing and autoglazing (Fn-FDPA, Fn-CDPA) displayed the roughest surfaces in ultra low-fusing ceramic (Finesse). Autoglazing alone and polishing displayed the roughest surfaces in low-fusing ceramic material (Om-AUG, Om-POL).

Для цитирования: Dalkiz Mehmet, Sipahi Cumhur, Beydemir Bedri. Effects of six surface treatment methods on the surface roughness of a low-fusing and an ultra low-fusing feldspathic ceramic material.. Journal of prosthodontics : official journal of the American College of Prosthodontists. 2008. DOI: 10.1111/j.1532-849x.2008.00410.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.