First report of image integration of cine-angiography with 3D electro-anatomical mapping of the right ventricle in postoperative tetralogy of Fallot.

Russo Mario Salvatore, Righi Daniela, Di Mambro Corrado, Ruoppolo Valentina, Silvetti Massimo Stefano, Drago Fabrizio

Клинический случайСтатьяПеревод в очереди

Аннотация

Ventricular tachycardia and, more rarely, sudden cardiac death are potential complications affecting the long-term outcome after Tetralogy of Fallot (ToF) repair. Intraventricular septal scar, fibro-fatty substitution around infundibular resection and patchy myocardial fibrosis may provide anatomical substrates of abnormal depolarization and repolarization causing reentrant ventricular arrhythmias. Recently, three-dimensional electro-anatomical mapping (3D EAM) has allowed to investigate the electro-anatomical status of the right ventricle. Radiation exposure during cardiac electrophysiological procedures is still a major concern. We report the first case of 3D mapping of the right ventricle in a postoperative ToF patient performed with a new module of the CARTO® 3 System-the CARTOUnivu™ Module-that combines, simultaneously, fluoroscopic images or cine-angiographic sequences with 3D cardiac mapping to allow real-time visualization of the electrocatheter during the 3D EAM reconstruction. The same volume, previously evaluated with cardiac MRI, was mapped. A perfect match of the diastolic edges of the RV obtained either by cine-loop acquisition during contrast fluoroscopy and by the 3D EAM, was observed. The fluoroscopy time for 3D EAM was 10 s. In conclusion, CARTOUnivu™ Module can integrate, in real time, fluoroscopic images/cine-angiography in virtual biplane view and the 3D EAM allowing a contextual visualization of position and movement of all electrocatheters. This can further increase the accuracy of the 3D EAM in very complex-operated congenital heart diseases, even decreasing radiation exposure.

Для цитирования: Russo Mario Salvatore, Righi Daniela, Di Mambro Corrado, Ruoppolo Valentina, Silvetti Massimo Stefano, Drago Fabrizio. First report of image integration of cine-angiography with 3D electro-anatomical mapping of the right ventricle in postoperative tetralogy of Fallot.. The international journal of cardiovascular imaging. 2014. DOI: 10.1007/s10554-014-0512-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.