MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jmrs.70033

Медицинская библиотека · Journal of medical radiation sciences · 2025

Magnetic Resonance Guided Radiation Therapy (MRgRT) Prostate Motion and Margins.

Peng Sammi, Courtot Tegan, Lye Jessica, Foroudi Farshad, Tacey Mark, Joon Daryl Lim, Chao Michael, Choong Ee Siang

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Systematic and random errors in radiation dose delivery necessitate the use of planning target volume (PTV) margins to ensure adequate clinical target volume (CTV) treatment. Advances in magnetic resonance-guided radiation therapy (MRgRT) have enabled improved imaging with possible margin reduction; however, the optimal PTV margins remain uncertain. This study aimed to evaluate the adaptive radiotherapy component of intra-fractional prostate movement in MRgRT for prostate cancer (PCa) patients and determine appropriate PTV margins.

METHODS

This study retrospectively analyzed 18 PCa patients treated using a 1.5 T MR-Linac. The initial fusion MR and verification MR scans were registered offline to assess prostate displacement between the two scans in the anterior-posterior (AP), left-right (LR) and superior-inferior (SI) directions. Random and systematic errors were calculated, and the PTV margins were determined using the Van Herk formula.

RESULTS

The average time between MR scans was 22 min (range 9-54 min) compared to an average beam-on time of 6 min (range 2-11 min). Mean and standard deviation of translational displacement was 1.2 ± 0.9 mm in the AP, 0.6 ± 0.5 mm in the LR, and 1.1 ± 0.8 mm in the SI directions. The calculated PTV margin was 3.2 mm in AP, 1.7 mm in LR, and 3.2 mm in SI directions. There was an observed trend of increased prostate motion with increased treatment duration.

CONCLUSION

MRgRT facilitates PTV margin reduction for PCa; however, our findings suggest that increased on-couch time may be associated with greater prostate motion. Future studies with larger patient cohorts and real-time motion monitoring are recommended to optimise margin strategies.

Для цитирования: Peng Sammi, Courtot Tegan, Lye Jessica, Foroudi Farshad, Tacey Mark, Joon Daryl Lim, Chao Michael, Choong Ee Siang. Magnetic Resonance Guided Radiation Therapy (MRgRT) Prostate Motion and Margins.. Journal of medical radiation sciences. 2025. DOI: 10.1002/jmrs.70033.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.