MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/cncr.11278

Медицинская библиотека · Cancer · 2003

False-negative core needle biopsies of the breast: an analysis of clinical, radiologic, and pathologic findings in 27 concecutive cases of missed breast cancer.

Shah Varsha I, Raju Usha, Chitale Dhananjay, Deshpande Vikram, Gregory Nancy, Strand Vernon

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

A benign diagnosis in a core needle biopsy (CNBx) of the breast performed for a clinically and/or radiologically suspicious abnormality is often due to a nonrepresentative sample. However, the discordance may not be recognized, resulting in a logistic delay in the diagnosis.

METHODS

Twenty-seven false-negative CNBxs were identified in 952 consecutive CNBxs of the breast (653 benign, 266 malignant, and 33 atypical) performed during a 1-year period. Biopsies were analyzed with respect to clinical and radiologic findings, biopsy type, type of malignancy, and interval between the original CNBx and final diagnosis. Four hundred thirty-eight (67%) of the patients with a benign CNBx diagnosis either underwent excision or had a minimum of 1-year follow-up (mean, 35.6 months; median, 36 months).

RESULTS

The cancers missed on CNBx included 6 ductal carcinomas in situ, 17 invasive ductal carcinomas, 3 invasive lobular carcinomas, and 1 non-Hodgkin lymphoma. The overall false-negative rate was 9.1%. For palpable lesions, ultrasound-guided CNBx had a lower rate of missed cancer (3.6%) compared with CNBx without image guidance (13.3%). The false-negative rate for vacuum assisted CNBx biopsy was 7.6% (3.3% for the 11-gauge needle, 22.2% for the 14-gauge needle; 5.6% for nonpalpable mass lesions, 8.2% for microcalcifications). In all seven false-negative CNBxs performed by radiologists, the discordance between the radiologic and pathologic findings was promptly recognized due to their standard follow-up protocol. The discordance between the degree of clinical suspicion, radiologic impression, and the pathologic findings was not immediately recognized in 5 of 20 false-negative CNBxs performed by surgeons (4 without radiologic guidance and 1 with ultrasound guidance), resulting in a delay in the diagnosis ranging from 112-336 days.

CONCLUSIONS

A false-negative diagnosis of breast carcinoma was found to be more common in CNBx performed without image guidance but occurred to a lesser degree in image-guided biopsies. A delay in diagnosis can be avoided by establishing a standard post-CNBx follow-up protocol.

Для цитирования: Shah Varsha I, Raju Usha, Chitale Dhananjay, Deshpande Vikram, Gregory Nancy, Strand Vernon. False-negative core needle biopsies of the breast: an analysis of clinical, radiologic, and pathologic findings in 27 concecutive cases of missed breast cancer.. Cancer. 2003. DOI: 10.1002/cncr.11278.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.