Quantitative assessment of right ventricular function and pulmonary regurgitation in surgically repaired tetralogy of Fallot using 256-slice CT: comparison with 3-Tesla MRI.

Yamasaki Yuzo, Nagao Michinobu, Yamamura Kenichiro, Yonezawa Masato, Matsuo Yoshio, Kawanami Satoshi, Kamitani Takeshi, Higuchi Ko, Sakamoto Ichiro, Shiokawa Yuichi, Yabuuchi Hidetake, Honda Hiroshi

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

To compare 256-slice cardiac computed tomography (CCT) with cardiac magnetic resonance (CMR) imaging to assess right ventricular (RV) function and pulmonary regurgitant fraction (PRF) in patients with repaired tetralogy of Fallot (TOF).

METHODS

Thirty-three consecutive patients with repaired TOF underwent retrospective ECG-gated CCT and 3-Tesla CMR. RV and left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and ejection fraction (EF) were measured using CCT and CMR. PRF-CCT (%) was defined as (RVSV - LVSV)/RVSV. PRF-CMR (%) was measured by the phase-contrast method. Repeated measurements were performed to determine intra- and interobserver variability.

RESULTS

CCT measurements, including PRF, correlated highly with the CMR reference (r = 0.71-0.96). CCT overestimated RVEDV (mean difference, 17.1 ± 2.9 ml), RVESV (12.9 ± 2.1 ml) and RVSV (4.2 ± 2.0 ml), and underestimated RVEF (-2.6 ± 1.0%) and PRF (-9.1 ± 2.0%) compared with CMR. The limits of agreement between CCT and CMR were in a good range for all measurements. The variability in CCT measurements was lower than those in CMR. The estimated effective radiation dose was 7.6 ± 2.6 mSv.

CONCLUSIONS

256-slice CCT can assess RV function and PRF with relatively low dose radiation exposure in patients with repaired TOF, but overestimates RV volume and underestimates PRF.

KEY POINTS: 256-slice CT assessment of RV function is highly reproducible in repaired TOF. Pulmonary regurgitation can be evaluated by biventricular systolic volume difference. CT overestimates RV volume and underestimates pulmonary regurgitation, compared with MRI.

Для цитирования: Yamasaki Yuzo, Nagao Michinobu, Yamamura Kenichiro, Yonezawa Masato, Matsuo Yoshio, Kawanami Satoshi, Kamitani Takeshi, Higuchi Ko, Sakamoto Ichiro, Shiokawa Yuichi, Yabuuchi Hidetake, Honda Hiroshi. Quantitative assessment of right ventricular function and pulmonary regurgitation in surgically repaired tetralogy of Fallot using 256-slice CT: comparison with 3-Tesla MRI.. European radiology. 2014. DOI: 10.1007/s00330-014-3344-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.