MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.vetimm.2024.110853

Медицинская библиотека · Veterinary immunology and immunopathology · 2024

Solving technical issues in flow cytometry to characterize porcine CD8α/β expressing lymphocytes.

Ringl Florian, Stadler Maria, van Dongen Katinka A, Adib Razavi Mahsa, Saalmüller Armin, Mair Kerstin H

СтатьяПеревод в очереди

Аннотация

The CD8 molecule is a cell surface receptor and well described as co-receptor on T cells, binding directly to the major histocompatibility complex class I on antigen presenting cells. CD8 antigens are comprised of two distinct polypeptide chains, the α and the β chain. In the pig, the CD8 receptor is expressed by several lymphocyte subsets, including Natural Killer cells, γδ T cells and antigen experienced CD4+ αβ T cells. On these cell populations CD8 is expressed as αα homodimers. Porcine cytolytic T cells on the other hand exclusively express CD8 αβ heterodimers. Several monoclonal antibodies (mAbs) for either of the two chains are available and are frequently used in flow cytometry. We observed that distinct combinations of mAb clones for CD8α and CD8β chains can cause troubles in multi-color staining panels. Therefore, we aimed for an in-depth study of the usage of different CD8-specific mAb clones and optimizing co-staining strategies for flow cytometry. We tested mAb clones 11/295/33 and 76-2-11 for the detection of CD8α and mAb clones PPT23 and PG164A for the detection of CD8β. The results indicate that the CD8α clone 11/295/33 should not be used together with either of the two CD8β clones in the same incubation step, as co-staining led to a highly reduced ability of CD8β mAb binding and loss in signal in flow cytometry. This can lead to potential false results in detecting CD8αβ cytolytic T cells. In case of the CD8α mAb clone 76-2-11, no inhibition in binding of either CD8β mAb clones was observed, making it the preferred choice in multi-color staining panels. The obtained data will help in future panel designs for flow cytometry in the pig and therefore improving studies of porcine immune cells.

Для цитирования: Ringl Florian, Stadler Maria, van Dongen Katinka A, Adib Razavi Mahsa, Saalmüller Armin, Mair Kerstin H. Solving technical issues in flow cytometry to characterize porcine CD8α/β expressing lymphocytes.. Veterinary immunology and immunopathology. 2024. DOI: 10.1016/j.vetimm.2024.110853.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.