MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12872-021-02270-5

Медицинская библиотека · BMC cardiovascular disorders · 2021

The short-term safety and effectiveness of a new distal perforating stent graft in Type B aortic dissection: a retrospective study.

Liu Xunqiang, Ji Wenkai, Tian Min, Chen Huanjun, Li Cuihong, Zhang Liqiong, Yang Ying, Wang Jifeng, Ji Min, Yang Chunxin, Zhu Enshuai, Cong Lei, Zhang Xili, Zhou Xiaona, Liu Hailong, Wang Jiaping, Tan Jing, Zhang Jinhui

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Spinal artery ischemia (SCI) events can result from over coverage of the descending thoracic aorta with a coated stent during Thoracic Endovascular Aortic Repair (TEVAR). The aim of this study was to determine whether a new distal perforating stent could reduce the incidence of spinal cord ischemia while remodeling the true lumen.

METHODS

TBAD patients treated with Talos stent in the vascular surgery Department of Yan 'an Hospital affiliated to Kunming Medical University between December 2017 and October 2019 were retrospectively analyzed to investigate the short-term safety and effectiveness of Talos stent.

RESULTS

A total of the 20 patients, including 14 males and 6 females, with an average age of 52.65 ± 8.98 years (range 37-68 years), were included in the analysis. Stent-grafts were successfully implanted in all patients under local anesthesia, with a technical success rate of 100%. The average operation time was 50.75 ± 13.01 min. A total of 2 cases (10%) presented chest pain associated with intercostal artery ischemia that was relieved on the 3rd and 5th postoperative day, respectively. Postoperative mean follow-up was 16.15 ± 3.99 months. No paraplegia or other complications occurred. And stenting did not induce new tears. No migration, deformation, or fracture of the stents occurred. There was a significant difference in the remolding of the true lumen preoperatively and at 12 months postoperatively (P < 0.05).

CONCLUSIONS

Talos stent has achieved satisfactory clinical treatment results in short term.

Для цитирования: Liu Xunqiang, Ji Wenkai, Tian Min, Chen Huanjun, Li Cuihong, Zhang Liqiong, Yang Ying, Wang Jifeng, Ji Min, Yang Chunxin, Zhu Enshuai, Cong Lei, Zhang Xili, Zhou Xiaona, Liu Hailong, Wang Jiaping, Tan Jing, Zhang Jinhui. The short-term safety and effectiveness of a new distal perforating stent graft in Type B aortic dissection: a retrospective study.. BMC cardiovascular disorders. 2021. DOI: 10.1186/s12872-021-02270-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.