Mandibular Denture Base Deformation with Locator and Ball Attachments of Implant-Retained Overdentures.

ELsyad Moustafa Abdou, Errabti Hatem Mokhtar, Mustafa Aisha Zakaria

СтатьяПеревод в очереди

Аннотация

PURPOSE: The aim of this in vitro study was to evaluate and compare mandibular denture base deformation between ball and Locator attachments of implant-retained overdentures.

MATERIALS AND

METHODS

An experimental acrylic model covered with resilient silicone mucosal simulation was constructed. Two laboratory implants were placed in the canine areas of the model. Two duplicate experimental overdentures were constructed and connected to the implants with either ball (GI) or Locator (GII) attachments. To measure overdenture strain around the attachments, 3 strain gauges were attached to the lingual polished surface of the overdentures opposite to the right implant (loading side) 2 mm above the attachment level (Ch1), at the attachment level (Ch2), and 2 mm below the attachment level (Ch3). Another 3 gauges were bonded opposite to the left implant (non-loading side) in the same manner (Ch6, Ch7, and Ch8). To measure strain at the midline of the overdentures, two strain gauges were attached in the midline at 5 mm intervals (Ch4 and Ch5). A universal testing device was used to deliver vertical static load of 50 N unilaterally and bilaterally to the first molar area to measure strain using a multi-channel digital strain meter.

RESULTS

During bilateral load application, GII recorded higher compressive strains than GI at the majority of channels. During unilateral load application, GI recorded higher tensile strains at Ch1, Ch2, and Ch3, and GII recorded higher strains than GI at Ch6, Ch7, and Ch8. During bilateral loading the highest strain was concentrated at Ch5 for both groups. During unilateral loading, the highest strain was concentrated at Ch2 for GI, and at Ch5 for GII.

CONCLUSION

Ball attachments for implant-retained overdentures were associated with significant mandibular denture base deformation over the implants compared to Locator attachments. Therefore, denture base reinforcement may be recommended with ball attachmentz to increase fracture resistance of the base.

Для цитирования: ELsyad Moustafa Abdou, Errabti Hatem Mokhtar, Mustafa Aisha Zakaria. Mandibular Denture Base Deformation with Locator and Ball Attachments of Implant-Retained Overdentures.. Journal of prosthodontics : official journal of the American College of Prosthodontists. 2015. DOI: 10.1111/jopr.12356.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.