MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clinbiomech.2017.01.016

Медицинская библиотека · Clinical biomechanics (Bristol, Avon) · 2017

Effects of hip joint transverse plane range of motion with a modeled effusion and capsular tear: A cadaveric study.

Hebert Casey, Smyth Mark P, Woodard Erik, Bills Collin C, Mihalko Marc J, Mihalko William M

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Multiple factors contribute to range of motion of the hip joint in the transverse plane: bony anatomy, hip capsule, corresponding ligaments, articular labrum, ligamentum teres, and negative intra-articular pressure. We hypothesized that violation of the negative pressure of the hip and simulation of an effusion would increase range of motion in the transverse plane in a cadaver model.

METHODS

Ten hip specimens were obtained and dissected with the femur and iliac wing mounted in a custom joint-testing rig in neutral position. Specimens were tested at 0 and at 90° of flexion with 1.5Nm internal and external rotational torque. Three conditions were assessed: (1) intact specimen, (2) an effusion modeled by a 10ml saline infusion, and (3) a capsular tear.

FINDINGS: The modeled effusion decreased rotational range of motion limits in both 0 and 90° of flexion, with a greater effect on the specimens at 0° flexion in external rotation with 4.1° less external rotation (p=0.009). A modeled capsular tear increased rotational motion limits in 0° of flexion in both internal and external rotation and in 90° flexion in internal rotation only (p<0.025).

INTERPRETATION: An effusion may decrease the rotation of the hip, and a capsular tear may increase its rotation. This should be considered in hips with traumatic capsular tears or arthroscopic portals.

Для цитирования: Hebert Casey, Smyth Mark P, Woodard Erik, Bills Collin C, Mihalko Marc J, Mihalko William M. Effects of hip joint transverse plane range of motion with a modeled effusion and capsular tear: A cadaveric study.. Clinical biomechanics (Bristol, Avon). 2017. DOI: 10.1016/j.clinbiomech.2017.01.016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.